North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
9 Saltwater Crescent North Kellyville NSW 2155
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 3 kW of solar panels and a 4,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 75 against 70 for energy and 42 against 40 for water.
Key features
- Windows
- 45 windows and glazed doors
- Wall insulation
- R3.6
- Roof and ceiling insulation
- Ceiling R2.5, R5, roof Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- Airconditioning ducting only (living area); 1-phase airconditioning, ducted (bedroom)
BASIX certificate
- Energy score
- 75 (target 70)
- Water score
- 42 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 39 MJ/m² a year
- Cooling load
- 21 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 424.6 m²
- Unconditioned floor area
- 8 m²
- Site area
- 844 m²
- Roof area
- 379 m²
- Garden area
- 422 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 3 kW
- Rainwater tank
- 4,000 litres
- Fixtures
- Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 149.7 m², single glazing 149.7 m²
Heating
- Living area: airconditioning ducting only; Energy rating: n/a
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 6 star (average zone)
Cooling
- Living area: airconditioning ducting only; Energy rating: n/a
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 6 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (polystyrene)
- Floor: suspended floor above enclosed subfloor, plywood; frame: timber - H2 treated softwood (no added insulation)
- Floor: suspended floor above open subfloor, plywood; frame: timber - H2 treated softwood (no added insulation)
- Floor: suspended floor above garage, plywood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (polystyrene)
- External wall: brick veneer; frame: timber - H2 treated softwood (polystyrene)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (polystyrene)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (polystyrene)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1784617S_03, issued 27 February 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- BERS Pro v5.2.3 (3.23)
- Rated on
- 15 Nov 2024
- Wall insulation
- R3.6
- Ceiling insulation
- R2.5, R5
- Floor insulation
- R2.5, R3.6
- LED downlights
- 169
- Living room glazing by direction
- NE 2.6 m², SE 4.3 m²
- All glazing by direction
- N 3.2 m², NE 46.6 m², SE 44.9 m², SW 18.4 m², NW 39.9 m²
Roof
- Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
Window schedule
- Garage-GF ALU-004-002-001 W14: 600 × 2,170 mm facing SW
- Formal Liv-GF ALU-010-005-001 W1-Part: 3,000 × 3,000 mm facing NW
- Formal Liv-GF ALU-012-003-001 W1-Part: 3,000 × 565 mm facing N
- Formal Liv-GF ALU-010-005-001 W1-Part: 3,000 × 1,260 mm facing NE
- Formal Liv-GF ALU-012-003-001 W2-Part: 3,000 × 1,500 mm facing NE
- Bedroom 1-GF ALU-004-002-001 W13: 1,460 × 1,810 mm facing SW
- Pooja-GF ALU-004-002-001 W3: 600 × 1,570 mm facing NE
- Hwy-GF ALU-020-001-001 D8-Part: 2,700 × 3,500 mm facing NE
- Study-GF ALU-010-005-001 W4: 2,400 × 970 mm facing NE
- Study-GF ALU-010-005-001 W5: 1,800 × 2,410 mm facing SE
- Media-GF ALU-004-002-001 W12: 900 × 3,000 mm facing SW
- Laundry-GF ALU-010-005-001 D10-W: 1,460 × 730 mm facing SW
- Ktch/Liv/Din-GF ALU-020-001-001 D8-Part: 2,700 × 1,310 mm facing NE
- Ktch/Liv/Din-GF ALU-010-005-001 W6: 3,000 × 2,650 mm facing NW
- Ktch/Liv/Din-GF ALU-010-005-001 W7: 3,000 × 970 mm facing NE
- Ktch/Liv/Din-GF ALU-010-005-001 W8: 3,000 × 970 mm facing NE
- Ktch/Liv/Din-GF ALU-012-003-001 W9: 3,000 × 2,410 mm facing SE
- Ktch/Liv/Din-GF ALU-020-001-001 D7: 3,300 × 5,000 mm facing SE
- Ktch/Liv/Din-GF ALU-012-003-001 W10: 600 × 2,410 mm facing SW
- Butlers-GF ALU-004-002-001 W11: 600 × 3,010 mm facing SW
- Void-FF ALU-012-003-001 W15: 2,700 × 1,500 mm facing NW
- Void-FF ALU-012-003-001 W1-Part: 2,700 × 3,000 mm facing NW
- Void-FF ALU-012-003-001 W1-Part: 2,700 × 565 mm facing N
- Void-FF ALU-012-003-001 W2-Part: 2,700 × 1,500 mm facing NE
- Void-FF ALU-012-003-001 W1-Part: 2,700 × 1,260 mm facing NE
- Rumpus-FF ALU-010-005-001 W16: 2,100 × 610 mm facing NE
- Rumpus-FF ALU-010-005-001 W17: 2,100 × 610 mm facing NE
- Rumpus-FF ALU-004-002-001 W18: 1,800 × 2,410 mm facing SE
- Bedroom 2-FF ALU-020-001-001 D9: 2,700 × 4,000 mm facing NW
- Bedroom 3-FF ALU-010-005-001 W32: 1,800 × 730 mm facing SW
- Bedroom 3-FF ALU-010-005-001 W33: 1,800 × 730 mm facing SW
- Ens/Bed 3-FF ALU-010-005-001 W30: 600 × 610 mm facing SW
- Ens/Bed 3-FF ALU-010-005-001 W31: 600 × 610 mm facing SW
- Bedroom 4-FF ALU-010-005-001 W26: 1,800 × 730 mm facing SW
- Bedroom 4-FF ALU-010-005-001 W27: 1,800 × 730 mm facing SW
- Ens/Bed 4-FF ALU-010-005-001 W28: 600 × 610 mm facing SW
- Ens/Bed 4-FF ALU-010-005-001 W29: 600 × 610 mm facing SW
- Robe/M.Bed-FF ALU-004-002-001 W19: 1,460 × 1,450 mm facing NE
- Master Bed-FF ALU-010-005-001 W20: 2,100 × 970 mm facing NE
- Master Bed-FF ALU-010-005-001 W21: 2,100 × 970 mm facing NE
- Master Bed-FF ALU-020-001-001 D6: 2,400 × 3,000 mm facing SE
- Master Bed-FF ALU-010-005-001 W22: 1,800 × 1,210 mm facing SE
- Her/M.Bed-FF ALU-010-005-001 W23: 1,800 × 850 mm facing SE
- Her/M.Bed-FF ALU-010-005-001 W24: 1,800 × 850 mm facing SE
- Ens/M.Bed-FF ALU-010-005-001 W25: 600 × 1,210 mm facing SW
Certificate 0011559952, issued 15 November 2024, from the council's DA documents. Verify this certificate
Other certificates for this address
BASIX certificate, certificate 1773136S_02, issued 15 November 2024
BASIX certificate
- Energy score
- 74 (target 70)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -75
- Heating load
- 36 MJ/m² a year
- Cooling load
- 24 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 436.4 m²
- Unconditioned floor area
- 8.1 m²
- Site area
- 844 m²
- Roof area
- 379 m²
- Garden area
- 359 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 5 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- uPVC frames 152.9 m², double glazing 152.9 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: suspended floor above open subfloor, particle board; frame: timber - untreated softwood (rockwool batts, roll or pump-in)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - untreated softwood (no added insulation)
- Floor: suspended floor above garage, particle board; frame: timber - untreated softwood (rockwool batts, roll or pump-in)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - untreated softwood (rockwool batts, roll or pump-in)
- External wall: framed (fibre cement sheet or boards); frame: timber - untreated softwood (rockwool batts, roll or pump-in)
- External garage wall: brick veneer; frame: timber - untreated softwood (rockwool batts, roll or pump-in)
- Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - untreated softwood (ceiling: rockwool batts, roll or pump-in; roof: foil backed blanket.)
Certificate 1773136S_02, issued 15 November 2024, from the council's DA documents.
Is this your home? Ask us to remove these details.