Skip to main content

7 Wedgetail Way West Pennant Hills NSW 2125

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 0.1 kW of solar panels and a 3,000 litre rainwater tank.

Key features

Windows
Up to aluminium frames 80.9 m², single glazing 3.9 m², double glazing 77 m²
Wall insulation
Fibreglass batts or roll
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

Built by Worthington Constructions.

BASIX certificate

Energy score
72 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
14 MJ/m² a year
Cooling load
16 MJ/m² a year
Bedrooms
5
Conditioned floor area
339.1 m²
Unconditioned floor area
18.5 m²
Site area
700 m²
Roof area
330 m²
Garden area
280 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
0.1 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 3 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 80.9 m², single glazing 3.9 m², double glazing 77 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (not specified)
  • Floor: above habitable rooms or mezzanine, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: suspended floor above garage, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: AAC veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: AAC veneer; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1770561S_03, issued 17 December 2024, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
17 Dec 2024

Certificate 0LB55KT5TW-01, issued 17 December 2024, from the council's DA documents. Verify this certificate

Other certificates for this address

BASIX certificate, certificate 1770561S, issued 28 October 2024

BASIX certificate

Energy score
72 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
13 MJ/m² a year
Cooling load
17 MJ/m² a year
Bedrooms
5
Conditioned floor area
340.6 m²
Unconditioned floor area
18.5 m²
Site area
700 m²
Roof area
330 m²
Garden area
280 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
0.1 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 3 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 80.9 m², single glazing 3.9 m², double glazing 77 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (not specified)
  • Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (no added insulation)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: AAC veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: AAC veneer; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1770561S, issued 28 October 2024, from the council's DA documents.

NatHERS certificate, certificate IXCY9LQHG1, issued 1 August 2024

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5 (3.22)
Rated on
1 Aug 2024

Certificate IXCY9LQHG1, issued 1 August 2024, from the council's DA documents. Verify this certificate

BASIX certificate, certificate 1758159S, issued 1 August 2024

BASIX certificate

Energy score
72 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
14 MJ/m² a year
Cooling load
16 MJ/m² a year
Bedrooms
5
Conditioned floor area
340.6 m²
Unconditioned floor area
18.5 m²
Site area
700 m²
Roof area
330 m²
Garden area
280 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
0.1 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 3 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 80.9 m², single glazing 3.9 m², double glazing 77 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (not specified)
  • Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (no added insulation)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: AAC veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: AAC veneer; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1758159S, issued 1 August 2024, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.