North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
7 Bouddi Circuit North Kellyville NSW 2155
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 2 kW of solar panels and a 4,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 80 against 70 for energy and 64 against 40 for water.
Key features
- Windows
- Up to composite frames 84.5 m², double glazing 84.5 m²
- Wall insulation
- Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: none
- Hot water
- Electric boosted solar with a performance of 31 to 35 STCs or better
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
Built by Westpac Construction.
BASIX certificate
- Energy score
- 80 (target 70)
- Water score
- 64 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 30 MJ/m² a year
- Cooling load
- 27 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 100 m²
- Unconditioned floor area
- 50 m²
- Site area
- 600 m²
- Roof area
- 153 m²
- Garden area
- 175 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Electric boosted solar with a performance of 31 to 35 STCs or better
- Solar panels
- 2 kW
- Rainwater tank
- 4,000 litres
- Fixtures
- Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- composite frames 84.5 m², double glazing 84.5 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (fibreglass batts or roll)
- Garage floor: concrete slab on ground (fibreglass batts or roll)
- External wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll)
- External wall: framed (fibre cement sheet or boards); frame: timber - untreated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / flat roof, concrete - bare internal, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: none.)
Certificate 1736120S_06, issued 14 October 2024, from the council's DA documents.
Other certificates for this address
BASIX certificate, certificate 1736120S_04, issued 1 May 2024
BASIX certificate
- Energy score
- 79 (target 70)
- Water score
- 64 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 30 MJ/m² a year
- Cooling load
- 29 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 100 m²
- Unconditioned floor area
- 50 m²
- Site area
- 600 m²
- Roof area
- 153 m²
- Garden area
- 175 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Electric boosted solar with a performance of 31 to 35 STCs or better
- Solar panels
- 2 kW
- Rainwater tank
- 4,000 litres
- Fixtures
- Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- composite frames 84.5 m², double glazing 84.5 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (fibreglass batts or roll)
- Garage floor: concrete slab on ground (fibreglass batts or roll)
- External wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll)
- External wall: framed (fibre cement sheet or boards); frame: timber - untreated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / flat roof, concrete - bare internal, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: none.)
Certificate 1736120S_04, issued 1 May 2024, from the council's DA documents.
BASIX certificate, certificate 1736120S, issued 16 February 2024
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 27 MJ/m² a year
- Cooling load
- 28 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 100 m²
- Unconditioned floor area
- 50 m²
- Site area
- 600 m²
- Roof area
- 153 m²
- Garden area
- 175 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Electric boosted solar with a performance of 31 to 35 STCs or better
- Solar panels
- 2 kW
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- composite frames 84.5 m², double glazing 84.5 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (fibreglass batts or roll)
- Garage floor: concrete slab on ground (fibreglass batts or roll)
- External wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll)
- External wall: framed (fibre cement sheet or boards); frame: timber - untreated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / flat roof, concrete - bare internal, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: none.)
Certificate 1736120S, issued 16 February 2024, from the council's DA documents.