North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
64 Burns Road Kellyville NSW 2155
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to 3 kW of solar panels and a 1,500 litre rainwater tank. It beat its BASIX water target, scoring 53 against 40.
Key features
- Windows
- Up to aluminium frames 103.3 m², double glazing 103.3 m²
- Wall insulation
- Fibreglass batts or roll+ foil/sarking; Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
Built by Kuver Homes.
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 53 (target 40)
- Thermal performance
- Pass
- Materials score
- -68
- Heating load
- 37 MJ/m² a year
- Cooling load
- 23 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 327 m²
- Unconditioned floor area
- 24 m²
- Site area
- 403 m²
- Roof area
- 207 m²
- Garden area
- 142 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 3 kW
- Rainwater tank
- 1,500 litres
- Fixtures
- Showerheads 4 star, toilets 3 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 103.3 m², double glazing 103.3 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (no added insulation)
- Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: AAC veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: concrete block/plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: AAC veneer; frame: timber - H2 treated softwood (foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1738311S_02, issued 22 April 2026, from the council's DA documents.
Is this your home? Ask us to remove these details.