North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
615 River Road Lower Portland NSW 2756
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to a 40,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 71 against 70 for energy and 54 against 40 for water.
Key features
- Windows
- Up to aluminium frames 22.8 m², double glazing 22.8 m²
- Wall insulation
- All external walls rockwool batts, roll or pump-in
- Roof and ceiling insulation
- Ceiling: rockwool batts, roll or pump-in; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, non ducted (living area and bedroom)
BASIX certificate
- Energy score
- 71 (target 70)
- Water score
- 54 (target 40)
- Thermal performance
- Pass
- Materials score
- 37
- Heating load
- 30 MJ/m² a year
- Cooling load
- 26 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 115.4 m²
- Unconditioned floor area
- 8.9 m²
- Site area
- 145 m²
- Roof area
- 77 m²
- Garden area
- 50 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Rainwater tank
- 40,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 22.8 m², double glazing 22.8 m²
Heating
- Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (no added insulation)
- External wall: framed (metal clad); frame: timber - H2 treated softwood. all external walls rockwool batts, roll or pump-in
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: rockwool batts, roll or pump-in; roof: foil backed blanket.)
Certificate 1795465S, issued 14 May 2025, from the council's DA documents.
Other certificates for this address
BASIX certificate, certificate 1735330S, issued 9 February 2024
BASIX certificate
- Energy score
- 72 (target 70)
- Water score
- 43 (target 40)
- Thermal performance
- Pass
- Materials score
- 35
- Heating load
- 30 MJ/m² a year
- Cooling load
- 25 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 115.1 m²
- Unconditioned floor area
- 8.7 m²
- Site area
- 145 m²
- Roof area
- 92 m²
- Garden area
- 69 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 5 stars
- Rainwater tank
- 2,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 22.8 m², double glazing 22.8 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (metal clad); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1735330S, issued 9 February 2024, from the council's DA documents.