52 Kooraban Crescent North Kellyville NSW 2155
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 5 stars out of 10. Its BASIX certificate commits it to 4 kW of solar panels and a 4,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 59 against 50 for energy and 55 against 40 for water.
Key features
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
Built by Btqe Constructions.
BASIX certificate
- Energy score
- 59 (target 50)
- Water score
- 55 (target 40)
- Thermal performance
- Pass
- Heating load
- 55 MJ/m² a year
- Cooling load
- 56 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 350.5 m²
- Unconditioned floor area
- 16.8 m²
- Site area
- 1,250 m²
- Roof area
- 261 m²
- Garden area
- 171 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 4 kW
- Rainwater tank
- 4,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Certificate 1373956S_04, issued 20 December 2023, from the council's DA documents.
NatHERS certificate
- Star rating
- 5 stars
- Rated with
- FirstRate5: 5.3.2b (3.21)
- Rated on
- 20 Dec 2023
Certificate HE1IWSTCVK-01, issued 20 December 2023, from the council's DA documents. Verify this certificate
Other certificates for this address
BASIX certificate, certificate 1373956S_02, issued 24 February 2023
BASIX certificate
- Energy score
- 59 (target 50)
- Water score
- 47 (target 40)
- Thermal performance
- Pass
- Heating load
- 53 MJ/m² a year
- Cooling load
- 54 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 350.5 m²
- Unconditioned floor area
- 16.8 m²
- Site area
- 1,250 m²
- Roof area
- 261 m²
- Garden area
- 171 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 4 kW
- Rainwater tank
- 4,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Certificate 1373956S_02, issued 24 February 2023, from the council's DA documents.
NatHERS certificate, certificate HE1IWSTCVK, issued 22 February 2023
NatHERS certificate
- Star rating
- 5.2 stars
- Rated with
- FirstRate5: 5.3.2b (3.21)
- Rated on
- 22 Feb 2023
Certificate HE1IWSTCVK, issued 22 February 2023, from the council's DA documents. Verify this certificate