North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
52 Keystone Way Gables NSW 2765
BASIX certificate and NatHERS rating
Finding the block on the map…
This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to 4 kW of solar panels. It beat its BASIX energy and water targets, scoring 92 against 70 for energy and 52 against 40 for water.
Key features
- Windows
- Up to aluminium frames 107.4 m², single glazing 32.5 m², double glazing 74.9 m²
- Wall insulation
- Fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 92 (target 70)
- Water score
- 52 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 28 MJ/m² a year
- Cooling load
- 31 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 327.3 m²
- Unconditioned floor area
- 23.6 m²
- Site area
- 467 m²
- Roof area
- 300 m²
- Garden area
- 233 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 4 kW
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 107.4 m², single glazing 32.5 m², double glazing 74.9 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: above habitable rooms or mezzanine, particle board; frame: laminated veneer lumber (LVL) (fibreglass batts or roll)
- Floor: suspended floor above garage, particle board; frame: laminated veneer lumber (LVL) (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: framed (metal clad); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1765854S_03, issued 5 June 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 7.1 stars
- Rated with
- FirstRate5: 5.5.5a (3.22)
- Rated on
- 24 Sep 2024
Certificate JES4CJGJAW, issued 24 September 2024, from the council's DA documents. Verify this certificate
Is this your home? Ask us to remove these details.