North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
52 Aplite Circuit Gables NSW 2765
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 2 kW of solar panels and a 3,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor.
Key features
- Windows
- 10 windows and glazed doors
- Wall insulation
- R2.5
- Roof and ceiling insulation
- Ceiling R6, R3, R4.1, roof Roof Tiles Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, medium colour
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -44
- Heating load
- 25 MJ/m² a year
- Cooling load
- 34 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 284.4 m²
- Unconditioned floor area
- 15 m²
- Site area
- 763 m²
- Roof area
- 271 m²
- Garden area
- 368 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 2 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 57.5 m², single glazing 57.5 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (no added insulation)
- Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1810697S_03, issued 23 February 2026, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- BERS Pro v5.2.6 (3.23)
- Rated on
- 29 Aug 2025
- Wall insulation
- R2.5
- Ceiling insulation
- R6, R3, R4.1
- Floor insulation
- R2.5, R2, R4.1
- LED downlights
- 63
- Living room glazing by direction
- N 2.5 m², E 18.6 m²
- All glazing by direction
- N 4.1 m², E 18.6 m², S 2.7 m², W 1.4 m²
Roof
- Roof Tiles Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, medium colour
Window schedule
- Kitchen/Living1 WID-106-003-002: 2,400 × 1,850 mm facing E
- Kitchen/Living1 WID-103-004-002: 2,400 × 650 mm facing E
- Kitchen/Living1 WID-103-004-002: 2,400 × 650 mm facing E
- Kitchen/Living1 WID-104-007-003: 2,400 × 4,600 mm facing E
- Kitchen/Living1 WID-103-004-002: 2,100 × 600 mm facing N
- Kitchen/Living1 WID-103-004-002: 2,100 × 600 mm facing N
- WIP WID-102-005-002: 600 × 1,500 mm facing S
- Garage 1 WID-102-001-003: 1,000 × 1,800 mm facing S
- VOID WID-106-003-002: 1,200 × 1,200 mm facing W
- Bedroom 1 WID-102-005-002: 600 × 2,600 mm facing N
Certificate 0012158929, issued 29 August 2025, from the council's DA documents. Verify this certificate
Other certificates for this address
BASIX certificate, certificate 1810697S_02, issued 26 November 2025
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -44
- Heating load
- 25 MJ/m² a year
- Cooling load
- 34 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 284.4 m²
- Unconditioned floor area
- 15 m²
- Site area
- 763 m²
- Roof area
- 271 m²
- Garden area
- 368 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 2 kW
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 57.5 m², single glazing 57.5 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (no added insulation)
- Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1810697S_02, issued 26 November 2025, from the council's DA documents.
Is this your home? Ask us to remove these details.