51 Gromark Terrace Gables NSW 2765
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to 2.5 kW of solar panels. It beat its BASIX water target, scoring 50 against 40.
Key features
- Windows
- Up to aluminium frames 81.5 m², double glazing 81.5 m²
- Wall insulation
- Fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 5.5 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Markorios & George.
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 50 (target 40)
- Thermal performance
- Pass
- Materials score
- -42
- Heating load
- 31 MJ/m² a year
- Cooling load
- 29 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 274 m²
- Unconditioned floor area
- 8 m²
- Site area
- 474 m²
- Roof area
- 241 m²
- Garden area
- 187 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 5.5 stars
- Solar panels
- 2.5 kW
- Fixtures
- Showerheads 4 star, toilets 3 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 81.5 m², double glazing 81.5 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (not specified)
- Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- Internal wall shared with garage: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1744467S_03, issued 30 July 2024, from the council's DA documents.
Other certificates for this address
BASIX certificate, certificate 1744467S_02, issued 20 May 2024
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 50 (target 40)
- Thermal performance
- Pass
- Materials score
- -42
- Heating load
- 29 MJ/m² a year
- Cooling load
- 29 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 274 m²
- Unconditioned floor area
- 8 m²
- Site area
- 474 m²
- Roof area
- 241 m²
- Garden area
- 187 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 5.5 stars
- Solar panels
- 2.5 kW
- Fixtures
- Showerheads 4 star, toilets 3 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 81.5 m², double glazing 81.5 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (not specified)
- Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- Internal wall shared with garage: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1744467S_02, issued 20 May 2024, from the council's DA documents.