Skip to main content

5052 Janpieter Road Gables NSW 2765

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to 3 kW of solar panels. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 73 against 70.

Key features

Windows
50 windows and glazed doors: Aluminium B DG Argon Fill High Solar Gain low-E -Clear; 502/504 Al Sliding Window SG 638CP; 541/542 Al Sliding Door SG 638CP and 2 more types
Wall insulation
R2.5
Roof and ceiling insulation
Ceiling R6.0, roof Cont:Attic-Continuous 1.8, light colour
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by Apple Homes.

BASIX certificate

Energy score
73 (target 70)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
44 MJ/m² a year
Cooling load
15 MJ/m² a year
Bedrooms
5
Conditioned floor area
724.5 m²
Unconditioned floor area
21.7 m²
Site area
2,004 m²
Roof area
1,076 m²
Garden area
861 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
3 kW
Fixtures
Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 187.3 m², single glazing 91.1 m², double glazing 96.2 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: brick veneer; frame: timber - untreated softwood. all external walls fibreglass batts or roll+ foil/sarking
  • External garage wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll+ foil/sarking)
  • Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1799276S_03, issued 15 July 2025, from the council's DA documents.

NatHERS certificate

Star rating
7.1 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
15 Jul 2025
Wall insulation
R2.5
Ceiling insulation
R6.0
Floor insulation
R2.5
Living room glazing by direction
NE 3.2 m², SE 9.2 m², SW 15.5 m², NW 12 m²
All glazing by direction
NE 43.4 m², SE 35.4 m², SW 52.5 m², NW 51.6 m²

Roof

  • Cont:Attic-Continuous 1.8, light colour

Window types

  • ALM-006-03 A Aluminium B DG Argon Fill High Solar Gain low-E -Clear: U-value 4.1, SHGC 0.52
  • AWS-001-19 A 502/504 Al Sliding Window SG 638CP: U-value 4.52, SHGC 0.59
  • AWS-011-18 A 541/542 Al Sliding Door SG 638CP: U-value 4.36, SHGC 0.59
  • AWS-066-03 A RES SERIES 516 FIXED WINDOW SG 638ComPlsClr: U-value 3.91, SHGC 0.62
  • AWS-007-07 A 516 Al Awining Window SG 6.38CP: U-value 4.92, SHGC 0.41

Window schedule

  • Media, window ALM-006-03 A: 900 × 3,000 mm facing NE
  • Bedroom Son 1, window AWS-001-19 A: 1,500 × 3,000 mm facing NE
  • WC Son 1, window AWS-001-19 A: 600 × 1,000 mm facing NE
  • Shower Son 1, window AWS-001-19 A: 600 × 1,000 mm facing NE
  • Shower Son 2, window AWS-001-19 A: 600 × 1,000 mm facing NE
  • WIR Son 2, window AWS-001-19 A: 1,200 × 1,800 mm facing NE
  • Bedroom Son 2, window AWS-001-19 A: 2,300 × 3,000 mm facing NW
  • Rumpus, window AWS-011-18 A: 2,400 × 2,400 mm facing NW
  • Rumpus, window AWS-066-03 A: 2,300 × 3,000 mm facing SW
  • P Bath, window AWS-001-19 A: 600 × 750 mm facing NW
  • Office, window AWS-001-19 A: 900 × 2,700 mm facing NE
  • Living, window AWS-007-07 A: 2,300 × 1,000 mm facing SE
  • Living, window AWS-007-07 A: 2,300 × 1,000 mm facing SE
  • Living, window AWS-007-07 A: 2,300 × 1,000 mm facing SE
  • Living, window AWS-007-07 A: 2,300 × 1,000 mm facing SE
  • Store, window AWS-007-07 A: 2,100 × 1,800 mm facing SE
  • Butlers, window AWS-001-19 A: 500 × 2,100 mm facing NW
  • Butlers, window AWS-001-19 A: 500 × 2,400 mm facing SW
  • Bedroom Guest, window AWS-001-19 A: 900 × 2,400 mm facing SW
  • ENS Guest, window AWS-001-19 A: 600 × 1,200 mm facing SW
  • ENS Daughter, window AWS-001-19 A: 600 × 1,200 mm facing SW
  • Bedroom Daughter, window AWS-001-19 A: 1,650 × 900 mm facing SW
  • Bedroom Daughter, window AWS-001-19 A: 1,650 × 900 mm facing SW
  • Study, window AWS-001-19 A: 1,400 × 1,000 mm facing SW
  • Shower Master, window AWS-001-19 A: 600 × 900 mm facing SW
  • ENS Master, window AWS-001-19 A: 900 × 1,600 mm facing SW
  • Bedroom Master, window AWS-011-18 A: 2,400 × 3,000 mm facing NW
  • Bedroom Master, window AWS-001-19 A: 1,650 × 900 mm facing SW
  • Bedroom Master, window AWS-001-19 A: 1,650 × 900 mm facing SW
  • Hallway1, window ALM-006-03 A: 2,300 × 2,700 mm facing NE
  • Hallway1, window ALM-006-03 A: 2,400 × 3,000 mm facing NE
  • Hallway1, window ALM-006-03 A: 2,300 × 2,700 mm facing NE
  • Hallway1, window ALM-006-03 A: 2,300 × 3,000 mm facing NE
  • Hallway1, window ALM-006-03 A: 2,400 × 1,800 mm facing NW
  • Kitchen/Living, window AWS-066-03 A: 2,300 × 2,700 mm facing NW
  • Kitchen/Living, window AWS-011-18 A: 2,400 × 3,600 mm facing SW
  • Kitchen/Living, window AWS-001-19 A: 1,800 × 900 mm facing NE
  • Kitchen/Living, window AWS-001-19 A: 1,800 × 900 mm facing NE
  • Garage, window AWS-001-19 A: 600 × 3,000 mm facing SW
  • Foyer, window ALM-006-03 A: 2,300 × 900 mm facing SE
  • Foyer, window ALM-006-03 A: 2,300 × 900 mm facing SE
  • Hallway2, window ALM-006-03 A: 2,300 × 2,400 mm facing SE
  • Hallway2, window ALM-006-03 A: 2,400 × 3,000 mm facing SE
  • Hallway2, window ALM-006-03 A: 2,300 × 2,400 mm facing SE
  • Hallway2, window ALM-006-03 A: 2,300 × 2,400 mm facing NW
  • Hallway2, window ALM-006-03 A: 2,300 × 2,400 mm facing NW
  • Hallway4, window ALM-006-03 A: 2,400 × 3,600 mm facing SW
  • Hallway4, window ALM-006-03 A: 2,400 × 3,600 mm facing NW
  • Hallway3, window ALM-006-03 A: 2,300 × 2,700 mm facing SW
  • Hallway3, window ALM-006-03 A: 2,300 × 2,700 mm facing SW

Certificate VNN1IJHL15-02, issued 15 July 2025, from the council's DA documents. Verify this certificate

Other certificates for this address

NatHERS certificate, certificate VNN1IJHL15-01, issued 16 June 2025

NatHERS certificate

Star rating
7.1 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
16 Jun 2025
Wall insulation
R2.5
Ceiling insulation
R6.0
Floor insulation
R2.5
Living room glazing by direction
NE 3.2 m², SE 9.2 m², SW 15.5 m², NW 12 m²
All glazing by direction
NE 45 m², SE 35.4 m², SW 54 m², NW 51.6 m²

Roof

  • Cont:Attic-Continuous 1.8, medium colour

Window types

  • ALM-006-03 A Aluminium B DG Argon Fill High Solar Gain low-E -Clear: U-value 4.1, SHGC 0.52
  • AWS-001-19 A 502/504 Al Sliding Window SG 638CP: U-value 4.52, SHGC 0.59
  • AWS-011-18 A 541/542 Al Sliding Door SG 638CP: U-value 4.36, SHGC 0.59
  • AWS-066-03 A RES SERIES 516 FIXED WINDOW SG 638ComPlsClr: U-value 3.91, SHGC 0.62
  • AWS-007-07 A 516 Al Awining Window SG 6.38CP: U-value 4.92, SHGC 0.41

Window schedule

  • Media, window ALM-006-03 A: 900 × 3,000 mm facing NE
  • Bedroom Son 1, window AWS-001-19 A: 1,500 × 3,000 mm facing NE
  • WC Son 1, window AWS-001-19 A: 600 × 1,000 mm facing NE
  • Shower Son 1, window AWS-001-19 A: 600 × 1,000 mm facing NE
  • Shower Son 2, window AWS-001-19 A: 600 × 1,000 mm facing NE
  • WIR Son 2, window AWS-001-19 A: 1,200 × 1,800 mm facing NE
  • Bedroom Son 2, window AWS-001-19 A: 2,300 × 3,000 mm facing NW
  • Rumpus, window AWS-011-18 A: 2,400 × 2,400 mm facing NW
  • Rumpus, window AWS-066-03 A: 2,300 × 3,000 mm facing SW
  • P Bath, window AWS-001-19 A: 600 × 750 mm facing NW
  • Office, window AWS-001-19 A: 1,500 × 2,700 mm facing NE
  • Living, window AWS-007-07 A: 2,300 × 1,000 mm facing SE
  • Living, window AWS-007-07 A: 2,300 × 1,000 mm facing SE
  • Living, window AWS-007-07 A: 2,300 × 1,000 mm facing SE
  • Living, window AWS-007-07 A: 2,300 × 1,000 mm facing SE
  • Store, window AWS-007-07 A: 2,100 × 1,800 mm facing SE
  • Butlers, window AWS-001-19 A: 500 × 2,100 mm facing NW
  • Butlers, window AWS-001-19 A: 500 × 2,400 mm facing SW
  • Bedroom Guest, window AWS-001-19 A: 1,500 × 2,400 mm facing SW
  • ENS Guest, window AWS-001-19 A: 600 × 1,200 mm facing SW
  • ENS Daughter, window AWS-001-19 A: 600 × 1,200 mm facing SW
  • Bedroom Daughter, window AWS-001-19 A: 1,650 × 900 mm facing SW
  • Bedroom Daughter, window AWS-001-19 A: 1,650 × 900 mm facing SW
  • Study, window AWS-001-19 A: 1,400 × 1,000 mm facing SW
  • Shower Master, window AWS-001-19 A: 600 × 900 mm facing SW
  • ENS Master, window AWS-001-19 A: 900 × 1,600 mm facing SW
  • Bedroom Master, window AWS-011-18 A: 2,400 × 3,000 mm facing NW
  • Bedroom Master, window AWS-001-19 A: 1,650 × 900 mm facing SW
  • Bedroom Master, window AWS-001-19 A: 1,650 × 900 mm facing SW
  • Hallway1, window ALM-006-03 A: 2,300 × 2,700 mm facing NE
  • Hallway1, window ALM-006-03 A: 2,400 × 3,000 mm facing NE
  • Hallway1, window ALM-006-03 A: 2,300 × 2,700 mm facing NE
  • Hallway1, window ALM-006-03 A: 2,300 × 3,000 mm facing NE
  • Hallway1, window ALM-006-03 A: 2,400 × 1,800 mm facing NW
  • Kitchen/Living, window AWS-066-03 A: 2,300 × 2,700 mm facing NW
  • Kitchen/Living, window AWS-011-18 A: 2,400 × 3,600 mm facing SW
  • Kitchen/Living, window AWS-001-19 A: 1,800 × 900 mm facing NE
  • Kitchen/Living, window AWS-001-19 A: 1,800 × 900 mm facing NE
  • Garage, window AWS-001-19 A: 600 × 3,000 mm facing SW
  • Foyer, window ALM-006-03 A: 2,300 × 900 mm facing SE
  • Foyer, window ALM-006-03 A: 2,300 × 900 mm facing SE
  • Hallway2, window ALM-006-03 A: 2,300 × 2,400 mm facing SE
  • Hallway2, window ALM-006-03 A: 2,400 × 3,000 mm facing SE
  • Hallway2, window ALM-006-03 A: 2,300 × 2,400 mm facing SE
  • Hallway2, window ALM-006-03 A: 2,300 × 2,400 mm facing NW
  • Hallway2, window ALM-006-03 A: 2,300 × 2,400 mm facing NW
  • Hallway4, window ALM-006-03 A: 2,400 × 3,600 mm facing SW
  • Hallway4, window ALM-006-03 A: 2,400 × 3,600 mm facing NW
  • Hallway3, window ALM-006-03 A: 2,300 × 2,700 mm facing SW
  • Hallway3, window ALM-006-03 A: 2,300 × 2,700 mm facing SW

Certificate VNN1IJHL15-01, issued 16 June 2025, from the council's DA documents. Verify this certificate

BASIX certificate, certificate 1799276S_02, issued 16 June 2025

BASIX certificate

Energy score
73 (target 70)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
43 MJ/m² a year
Cooling load
16 MJ/m² a year
Bedrooms
5
Conditioned floor area
724.5 m²
Unconditioned floor area
21.7 m²
Site area
2,004 m²
Roof area
1,076 m²
Garden area
861 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
3 kW
Fixtures
Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 187.3 m², single glazing 91.1 m², double glazing 96.2 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: brick veneer; frame: timber - untreated softwood. all external walls fibreglass batts or roll+ foil/sarking
  • External garage wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll+ foil/sarking)
  • Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1799276S_02, issued 16 June 2025, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.