Skip to main content

5 Milguy Avenue Castle Hill NSW 2154

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 2,500 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX water target, scoring 46 against 40.

Key features

Windows
25 windows and glazed doors: Timber A SG Clear; 100 SERIES - ALUMINIUM SLIDING WINDOW SG 6ET; 200 SERIES - ALUMINIUM AWNING WINDOW SG 6ET
Wall insulation
R2.5, R2.0
Roof and ceiling insulation
Ceiling R2.5, R7.0, roof Cont:Attic-Continuous 1.3, medium colour
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by Anr Essentials.

BASIX certificate

Energy score
72 (target 72)
Water score
46 (target 40)
Thermal performance
Pass
Materials score
-73
Heating load
15 MJ/m² a year
Cooling load
15 MJ/m² a year
Bedrooms
5
Conditioned floor area
293.6 m²
Unconditioned floor area
49.3 m²
Site area
723 m²
Roof area
295 m²
Garden area
181 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 6 stars
Rainwater tank
2,500 litres
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 69.9 m², timber frames 3 m², single glazing 72.8 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER > 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER > 4.0

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER > 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER > 4.0

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1780483S_03, issued 2 April 2025, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
2 Apr 2025
Wall insulation
R2.5, R2.0
Ceiling insulation
R2.5, R7.0
Floor insulation
R2.5, R2.0
Living room glazing by direction
N 7 m², E 6 m², S 1.7 m², W 14.9 m²
All glazing by direction
N 11.5 m², E 32.3 m², S 7.1 m², W 22.9 m²

Roof

  • Cont:Attic-Continuous 1.3, medium colour

Window types

  • TIM-001-01 W Timber A SG Clear: U-value 5.4, SHGC 0.56
  • SSW-001-13 A 100 SERIES - ALUMINIUM SLIDING WINDOW SG 6ET: U-value 4.28, SHGC 0.61
  • SSW-004-16 A 200 SERIES - ALUMINIUM AWNING WINDOW SG 6ET: U-value 5.06, SHGC 0.5

Window schedule

  • GARAGE, window SSW-001-13 A: 514 × 2,650 mm facing N
  • STUDY, window SSW-004-16 A: 2,050 × 1,450 mm facing E
  • WC, window SSW-001-13 A: 857 × 730 mm facing N
  • LDY, window TIM-001-01 W: 1,200 × 820 mm facing W
  • RUMPUS, window SSW-001-13 A: 2,050 × 3,130 mm facing W
  • RUMPUS, window SSW-001-13 A: 2,340 × 2,990 mm facing N
  • BUTLERS, window SSW-001-13 A: 700 × 1,810 mm facing S
  • G.ENS, window SSW-001-13 A: 857 × 850 mm facing S
  • GUEST BED, window SSW-004-16 A: 2,050 × 2,410 mm facing E
  • LOUNGE, window SSW-001-13 A: 2,600 × 400 mm facing E
  • LOUNGE, window SSW-001-13 A: 2,050 × 1,450 mm facing E
  • LOUNGE, window TIM-001-01 W: 1,200 × 1,640 mm facing E
  • LIV/KIT, window SSW-001-13 A: 2,340 × 3,610 mm facing W
  • LIV/KIT, window SSW-001-13 A: 700 × 2,410 mm facing S
  • MASTER BED, window SSW-004-16 A: 2,050 × 2,410 mm facing E
  • MASTER BED, window SSW-001-13 A: 600 × 2,050 mm facing S
  • F.G.BED, window SSW-001-13 A: 2,340 × 3,605 mm facing E
  • F.G.BED, window SSW-001-13 A: 600 × 2,050 mm facing N
  • BED 3, window SSW-001-13 A: 600 × 2,050 mm facing N
  • BED 3, window SSW-001-13 A: 1,200 × 2,410 mm facing W
  • BATH, window SSW-001-13 A: 900 × 1,450 mm facing W
  • M.ENS, window SSW-001-13 A: 900 × 1,090 mm facing S
  • BED 2, window SSW-001-13 A: 1,200 × 2,410 mm facing W
  • BED 2, window SSW-001-13 A: 600 × 2,050 mm facing S
  • GAMES, window SSW-001-13 A: 2,100 × 2,399 mm facing E

Certificate RCC2ITY4ZV-02, issued 2 April 2025, from the council's DA documents. Verify this certificate

Other certificates for this address

NatHERS certificate, certificate RCC2ITY4ZV-01, issued 21 January 2025

NatHERS certificate

Star rating
7.1 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
21 Jan 2025
Wall insulation
R2.5, R2.0
Ceiling insulation
R2.5, R6.0, R5.0
Floor insulation
R2.5, R2.0
Living room glazing by direction
N 7 m², E 6 m², S 1.7 m², W 13.4 m²
All glazing by direction
N 11.5 m², E 32.3 m², S 7.1 m², W 21.9 m²

Roof

  • Cont:Attic-Continuous 1.3, medium colour

Window types

  • TIM-001-01 W Timber A SG Clear: U-value 5.4, SHGC 0.56
  • SSW-001-13 A 100 SERIES - ALUMINIUM SLIDING WINDOW SG 6ET: U-value 4.28, SHGC 0.61
  • SSW-004-16 A 200 SERIES - ALUMINIUM AWNING WINDOW SG 6ET: U-value 5.06, SHGC 0.5

Window schedule

  • GARAGE, window SSW-001-13 A: 514 × 2,650 mm facing N
  • STUDY, window SSW-004-16 A: 2,050 × 1,450 mm facing E
  • WC, window SSW-001-13 A: 857 × 730 mm facing N
  • LDY, window TIM-001-01 W: 1,200 × 820 mm facing W
  • RUMPUS, window SSW-001-13 A: 2,050 × 2,410 mm facing W
  • RUMPUS, window SSW-001-13 A: 2,340 × 2,990 mm facing N
  • BUTLERS, window SSW-001-13 A: 700 × 1,810 mm facing S
  • G.ENS, window SSW-001-13 A: 857 × 850 mm facing S
  • GUEST BED, window SSW-004-16 A: 2,050 × 2,410 mm facing E
  • LOUNGE, window SSW-001-13 A: 2,600 × 400 mm facing E
  • LOUNGE, window SSW-001-13 A: 2,050 × 1,450 mm facing E
  • LOUNGE, window TIM-001-01 W: 1,200 × 1,640 mm facing E
  • LIV/KIT, window SSW-001-13 A: 2,340 × 3,610 mm facing W
  • LIV/KIT, window SSW-001-13 A: 700 × 2,410 mm facing S
  • MASTER BED, window SSW-004-16 A: 2,050 × 2,410 mm facing E
  • MASTER BED, window SSW-001-13 A: 600 × 2,050 mm facing S
  • F.G.BED, window SSW-001-13 A: 2,340 × 3,605 mm facing E
  • F.G.BED, window SSW-001-13 A: 600 × 2,050 mm facing N
  • BED 3, window SSW-001-13 A: 600 × 2,050 mm facing N
  • BED 3, window SSW-001-13 A: 1,200 × 2,410 mm facing W
  • BATH, window SSW-001-13 A: 1,200 × 1,450 mm facing W
  • M.ENS, window SSW-001-13 A: 900 × 1,090 mm facing S
  • BED 2, window SSW-001-13 A: 1,200 × 2,410 mm facing W
  • BED 2, window SSW-001-13 A: 600 × 2,050 mm facing S
  • GAMES, window SSW-001-13 A: 2,100 × 2,399 mm facing E

Certificate RCC2ITY4ZV-01, issued 21 January 2025, from the council's DA documents. Verify this certificate

BASIX certificate, certificate 1780483S_02, issued 21 January 2025

BASIX certificate

Energy score
72 (target 72)
Water score
46 (target 40)
Thermal performance
Pass
Materials score
-73
Heating load
15 MJ/m² a year
Cooling load
14 MJ/m² a year
Bedrooms
5
Conditioned floor area
293.6 m²
Unconditioned floor area
49.3 m²
Site area
723 m²
Roof area
295 m²
Garden area
181 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 6 stars
Rainwater tank
2,500 litres
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 69.9 m², timber frames 3 m², single glazing 72.8 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER > 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER > 4.0

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER > 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER > 4.0

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1780483S_02, issued 21 January 2025, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.