This home has a NatHERS rating of 7.2 stars out of 10. Its BASIX certificate commits it to 6 kW of solar panels. It beat its BASIX energy and water targets, scoring 91 against 70 for energy and 53 against 40 for water.

Key features

Windows
Up to aluminium frames 100.2 m², single glazing 28.3 m², double glazing 71.9 m²
Wall insulation
Fibreglass batts or roll; Fibreglass batts or roll+ foil/sarking
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by Orange Solutions.

BASIX certificate

Energy score
91 (target 70)
Water score
53 (target 40)
Materials score
-79
Heating load
33 MJ/m² a year
Cooling load
24 MJ/m² a year
Bedrooms
5
Conditioned floor area
398 m²
Unconditioned floor area
7 m²
Site area
572 m²
Roof area
232 m²
Garden area
80 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
6 kW
Fixtures
Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
aluminium frames 100.2 m², single glazing 28.3 m², double glazing 71.9 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - untreated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: AAC veneer; frame: timber - untreated softwood (fibreglass batts or roll)
  • External wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll+ foil/sarking)
  • External garage wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll+ foil/sarking)
  • Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1779207S_04, issued 22 June 2026, from the council's DA documents.

NatHERS certificate

Star rating
7.2 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
13 Jun 2026

Certificate QJVSD69GOR, issued 13 June 2026, from the council's DA documents. Verify this certificate

Other certificates for this address

BASIX certificate, certificate 1779207S_03, issued 25 February 2025

BASIX certificate

Energy score
91 (target 70)
Water score
53 (target 40)
Thermal performance
Pass
Materials score
-81
Heating load
35 MJ/m² a year
Cooling load
24 MJ/m² a year
Bedrooms
5
Conditioned floor area
398 m²
Unconditioned floor area
7 m²
Site area
572 m²
Roof area
232 m²
Garden area
80 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
6 kW
Fixtures
Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
aluminium frames 107 m², single glazing 20 m², double glazing 87 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - untreated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: AAC veneer; frame: timber - untreated softwood (fibreglass batts or roll)
  • External wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll+ foil/sarking)
  • External garage wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll+ foil/sarking)
  • Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1779207S_03, issued 25 February 2025, from the council's DA documents.

NatHERS certificate, certificate YJA8CSH35R-01, issued 9 January 2025

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
9 Jan 2025

Certificate YJA8CSH35R-01, issued 9 January 2025, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related