This home's BASIX certificate commits it to 32 kW of solar panels and a 12,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 92 against 70 for energy and 49 against 40 for water.
Key features
- Windows
- Up to aluminium frames 285.8 m², single glazing 285.8 m²
- Wall insulation
- Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil/sarking
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 92 (target 70)
- Water score
- 49 (target 40)
- Materials score
- -100
- Heating load
- 41 MJ/m² a year
- Cooling load
- 16 MJ/m² a year
- Bedrooms
- 11
- Conditioned floor area
- 1,323.1 m²
- Unconditioned floor area
- 11.7 m²
- Site area
- 20,212 m²
- Roof area
- 1,163 m²
- Garden area
- 500 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 32 kW
- Rainwater tank
- 12,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Maximum glazing
- aluminium frames 285.8 m², single glazing 285.8 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: no frame (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
- External wall: cavity brick; frame: no frame (fibreglass batts or roll)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: single skin masonry; frame: no frame (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1735817S_04, issued 1 July 2026, from the council's DA documents.
Other certificates for this address
BASIX certificate, certificate 1735817S_03, issued 28 May 2026
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 40 (target 40)
- Materials score
- -100
- Heating load
- 41 MJ/m² a year
- Cooling load
- 16 MJ/m² a year
- Bedrooms
- 11
- Conditioned floor area
- 1,323.1 m²
- Unconditioned floor area
- 11.7 m²
- Site area
- 20,212 m²
- Roof area
- 1,163 m²
- Garden area
- 500 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 32 kW
- Rainwater tank
- 12,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Maximum glazing
- aluminium frames 285.8 m², single glazing 285.8 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: no frame (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
- External wall: cavity brick; frame: no frame (fibreglass batts or roll)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: single skin masonry; frame: no frame (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1735817S_03, issued 28 May 2026, from the council's DA documents.
BASIX certificate, certificate 1735817S_02, issued 4 June 2024
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 34 MJ/m² a year
- Cooling load
- 23 MJ/m² a year
- Bedrooms
- 13
- Conditioned floor area
- 1,324.6 m²
- Unconditioned floor area
- 323.5 m²
- Site area
- 20,212 m²
- Roof area
- 1,770 m²
- Garden area
- 400 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 34.2 kW
- Rainwater tank
- 12,500 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Maximum glazing
- aluminium frames 454.8 m², single glazing 454.8 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: no frame (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
- External wall: cavity brick; frame: no frame (fibreglass batts or roll)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: single skin masonry; frame: no frame (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1735817S_02, issued 4 June 2024, from the council's DA documents.
BASIX certificate, certificate 1735817S, issued 14 February 2024
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 40 MJ/m² a year
- Cooling load
- 18 MJ/m² a year
- Bedrooms
- 13
- Conditioned floor area
- 1,324.4 m²
- Unconditioned floor area
- 323.5 m²
- Site area
- 20,212 m²
- Roof area
- 1,770 m²
- Garden area
- 400 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 34.2 kW
- Rainwater tank
- 12,500 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Maximum glazing
- aluminium frames 452.7 m², double glazing 452.7 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: no frame (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
- External wall: cavity brick; frame: no frame (fibreglass batts or roll)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: single skin masonry; frame: no frame (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1735817S, issued 14 February 2024, from the council's DA documents.
Is this your home? Ask us to remove these details.