Skip to main content

5 Alinda Close Middle Dural NSW 2158

BASIX certificate and NatHERS rating

Finding the block on the map…

This home's BASIX certificate commits it to 32 kW of solar panels and a 12,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 92 against 70 for energy and 49 against 40 for water.

Key features

Windows
Up to aluminium frames 285.8 m², single glazing 285.8 m²
Wall insulation
Fibreglass batts or roll
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil/sarking
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
92 (target 70)
Water score
49 (target 40)
Materials score
-100
Heating load
41 MJ/m² a year
Cooling load
16 MJ/m² a year
Bedrooms
11
Conditioned floor area
1,323.1 m²
Unconditioned floor area
11.7 m²
Site area
20,212 m²
Roof area
1,163 m²
Garden area
500 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
32 kW
Rainwater tank
12,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
aluminium frames 285.8 m², single glazing 285.8 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: no frame (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
  • External wall: cavity brick; frame: no frame (fibreglass batts or roll)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1735817S_04, issued 1 July 2026, from the council's DA documents.

Other certificates for this address

BASIX certificate, certificate 1735817S_03, issued 28 May 2026

BASIX certificate

Energy score
70 (target 70)
Water score
40 (target 40)
Materials score
-100
Heating load
41 MJ/m² a year
Cooling load
16 MJ/m² a year
Bedrooms
11
Conditioned floor area
1,323.1 m²
Unconditioned floor area
11.7 m²
Site area
20,212 m²
Roof area
1,163 m²
Garden area
500 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
32 kW
Rainwater tank
12,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
aluminium frames 285.8 m², single glazing 285.8 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: no frame (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
  • External wall: cavity brick; frame: no frame (fibreglass batts or roll)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1735817S_03, issued 28 May 2026, from the council's DA documents.

BASIX certificate, certificate 1735817S_02, issued 4 June 2024

BASIX certificate

Energy score
70 (target 70)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
34 MJ/m² a year
Cooling load
23 MJ/m² a year
Bedrooms
13
Conditioned floor area
1,324.6 m²
Unconditioned floor area
323.5 m²
Site area
20,212 m²
Roof area
1,770 m²
Garden area
400 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
34.2 kW
Rainwater tank
12,500 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
aluminium frames 454.8 m², single glazing 454.8 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: no frame (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
  • External wall: cavity brick; frame: no frame (fibreglass batts or roll)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1735817S_02, issued 4 June 2024, from the council's DA documents.

BASIX certificate, certificate 1735817S, issued 14 February 2024

BASIX certificate

Energy score
70 (target 70)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
40 MJ/m² a year
Cooling load
18 MJ/m² a year
Bedrooms
13
Conditioned floor area
1,324.4 m²
Unconditioned floor area
323.5 m²
Site area
20,212 m²
Roof area
1,770 m²
Garden area
400 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
34.2 kW
Rainwater tank
12,500 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
aluminium frames 452.7 m², double glazing 452.7 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: no frame (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
  • External wall: cavity brick; frame: no frame (fibreglass batts or roll)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1735817S, issued 14 February 2024, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related