North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
49 Aplite Circuit Gables NSW 2765
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to 6 kW of solar panels. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 80 against 70 for energy and 44 against 40 for water.
Key features
- Windows
- 26 windows and glazed doors: Manor Awning Window DG 4/12/4EA; Aluminium Sliding Window DG 4/8/4ET; Sliding Door DG 6.38CPClr/8/4 and 1 more types
- Wall insulation
- R3.0
- Roof and ceiling insulation
- Ceiling R6.0, roof Cont:Attic-Continuous 1.3, medium colour
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by S4 Constructions.
BASIX certificate
- Energy score
- 80 (target 70)
- Water score
- 44 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 36 MJ/m² a year
- Cooling load
- 23 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 310 m²
- Unconditioned floor area
- 12 m²
- Site area
- 756 m²
- Roof area
- 368 m²
- Garden area
- 50 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 6 kW
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Maximum glazing
- aluminium frames 80 m², double glazing 80 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - untreated softwood. all external walls fibreglass batts or roll+ foil/sarking
- External garage wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1798541S_02, issued 14 August 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 7.1 stars
- Rated with
- FirstRate5: 5.5.5a (3.22)
- Rated on
- 14 Aug 2025
- Wall insulation
- R3.0
- Ceiling insulation
- R6.0
- Floor insulation
- R2.0, R3.0, R2.5
- Living room glazing by direction
- N 18.6 m², E 21.5 m², S 7.2 m², W 9.3 m²
- All glazing by direction
- N 26 m², E 30.7 m², S 11.9 m², W 19.3 m²
Roof
- Cont:Attic-Continuous 1.3, medium colour
Window types
- DOW-005-02 A Manor Awning Window DG 4/12/4EA: U-value 3.41, SHGC 0.52
- DOW-018-02 A Aluminium Sliding Window DG 4/8/4ET: U-value 3.66, SHGC 0.58
- DOW-007-06 A Sliding Door DG 6.38CPClr/8/4: U-value 3.59, SHGC 0.5
- DOW-015-01 A Aluminium Fixed Light Window DG 4/12/4: U-value 3.59, SHGC 0.66
Window schedule
- Bedroom 3, window DOW-005-02 A: 2,100 × 610 mm facing W
- Bedroom 3, window DOW-005-02 A: 2,100 × 610 mm facing W
- Ensuite 3, window DOW-018-02 A: 1,200 × 610 mm facing W
- Ensuite 2, window DOW-018-02 A: 1,200 × 610 mm facing W
- Bedroom 2, window DOW-005-02 A: 2,100 × 610 mm facing W
- Bedroom 2, window DOW-005-02 A: 2,100 × 610 mm facing W
- Laundry, window DOW-005-02 A: 2,400 × 820 mm facing W
- Ensuite, window DOW-018-02 A: 1,200 × 610 mm facing W
- Ensuite, window DOW-018-02 A: 1,200 × 610 mm facing W
- Master Bedroom, window DOW-007-06 A: 2,700 × 1,810 mm facing E
- Master Bedroom, window DOW-018-02 A: 2,100 × 2,650 mm facing N
- Powder, window DOW-018-02 A: 600 × 1,210 mm facing E
- Pooja/Study, window DOW-005-02 A: 2,100 × 850 mm facing E
- Pooja/Study, window DOW-005-02 A: 2,100 × 850 mm facing E
- Butler's Kitchen, window DOW-018-02 A: 700 × 1,800 mm facing E
- Guest Bedroom, window DOW-005-02 A: 2,560 × 1,810 mm facing S
- Entry/Living, window DOW-015-01 A: 2,400 × 3,010 mm facing N
- Kitchen/Living/-Dining, window DOW-018-02 A: 1,500 × 2,650 mm facing E
- Kitchen/Living/-Dining, window DOW-018-02 A: 1,500 × 2,650 mm facing E
- Kitchen/Living/-Dining, window DOW-015-01 A: 600 × 3,450 mm facing N
- Kitchen/Living/-Dining, window DOW-007-06 A: 2,700 × 3,450 mm facing N
- Kitchen/Living/-Dining, window DOW-007-06 A: 2,700 × 3,450 mm facing E
- Kitchen/Living/-Dining, window DOW-015-01 A: 730 × 4,000 mm facing E
- Kitchen/Living/-Dining, window DOW-015-01 A: 2,400 × 3,010 mm facing S
- Kitchen/Living/-Dining, window DOW-007-06 A: 2,700 × 3,450 mm facing W
- Theatre, window DOW-015-01 A: 600 × 3,010 mm facing N
Certificate BWL4Z73GMR-01, issued 14 August 2025, from the council's DA documents. Verify this certificate
Other certificates for this address
BASIX certificate, certificate 1798541S, issued 4 June 2025
BASIX certificate
- Energy score
- 80 (target 70)
- Water score
- 44 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 36 MJ/m² a year
- Cooling load
- 22 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 310 m²
- Unconditioned floor area
- 12 m²
- Site area
- 756 m²
- Roof area
- 368 m²
- Garden area
- 50 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 6 kW
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Maximum glazing
- aluminium frames 80 m², double glazing 80 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - untreated softwood. all external walls fibreglass batts or roll+ foil/sarking
- External garage wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1798541S, issued 4 June 2025, from the council's DA documents.
NatHERS certificate, certificate BWL4Z73GMR, issued 3 June 2025
NatHERS certificate
- Star rating
- 7.1 stars
- Rated with
- FirstRate5: 5.5.5a (3.22)
- Rated on
- 3 Jun 2025
- Wall insulation
- R3.0
- Ceiling insulation
- R6.0
- Floor insulation
- R2.0, R3.0, R2.5
- Living room glazing by direction
- N 18.6 m², E 21.5 m², S 7.2 m², W 9.3 m²
- All glazing by direction
- N 26 m², E 30.7 m², S 11.9 m², W 18.1 m²
Roof
- Cont:Attic-Continuous 1.3, medium colour
Window types
- DOW-005-02 A Manor Awning Window DG 4/12/4EA: U-value 3.41, SHGC 0.52
- DOW-018-02 A Aluminium Sliding Window DG 4/8/4ET: U-value 3.66, SHGC 0.58
- DOW-007-06 A Sliding Door DG 6.38CPClr/8/4: U-value 3.59, SHGC 0.5
- DOW-015-01 A Aluminium Fixed Light Window DG 4/12/4: U-value 3.59, SHGC 0.66
Window schedule
- Bedroom 3, window DOW-005-02 A: 2,100 × 610 mm facing W
- Ensuite 3, window DOW-018-02 A: 1,200 × 610 mm facing W
- Ensuite 2, window DOW-018-02 A: 1,200 × 610 mm facing W
- Bedroom 2, window DOW-005-02 A: 2,100 × 610 mm facing W
- Bedroom 2, window DOW-005-02 A: 2,100 × 610 mm facing W
- Laundry, window DOW-005-02 A: 2,400 × 820 mm facing W
- Ensuite, window DOW-018-02 A: 1,200 × 610 mm facing W
- Ensuite, window DOW-018-02 A: 1,200 × 610 mm facing W
- Master Bedroom, window DOW-007-06 A: 2,700 × 1,810 mm facing E
- Master Bedroom, window DOW-018-02 A: 2,100 × 2,650 mm facing N
- Powder, window DOW-018-02 A: 600 × 1,210 mm facing E
- Pooja/Study, window DOW-005-02 A: 2,100 × 850 mm facing E
- Pooja/Study, window DOW-005-02 A: 2,100 × 850 mm facing E
- Butler's Kitchen, window DOW-018-02 A: 700 × 1,800 mm facing E
- Guest Bedroom, window DOW-005-02 A: 2,560 × 1,810 mm facing S
- Entry/Living, window DOW-015-01 A: 2,400 × 3,010 mm facing N
- Kitchen/Living/-Dining, window DOW-018-02 A: 1,500 × 2,650 mm facing E
- Kitchen/Living/-Dining, window DOW-018-02 A: 1,500 × 2,650 mm facing E
- Kitchen/Living/-Dining, window DOW-015-01 A: 600 × 3,450 mm facing N
- Kitchen/Living/-Dining, window DOW-007-06 A: 2,700 × 3,450 mm facing N
- Kitchen/Living/-Dining, window DOW-007-06 A: 2,700 × 3,450 mm facing E
- Kitchen/Living/-Dining, window DOW-015-01 A: 730 × 4,000 mm facing E
- Kitchen/Living/-Dining, window DOW-015-01 A: 2,400 × 3,010 mm facing S
- Kitchen/Living/-Dining, window DOW-007-06 A: 2,700 × 3,450 mm facing W
- Theatre, window DOW-015-01 A: 600 × 3,010 mm facing N
Certificate BWL4Z73GMR, issued 3 June 2025, from the council's DA documents. Verify this certificate
Is this your home? Ask us to remove these details.