Skip to main content

49 Aplite Circuit Gables NSW 2765

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to 6 kW of solar panels. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 80 against 70 for energy and 44 against 40 for water.

Key features

Windows
26 windows and glazed doors: Manor Awning Window DG 4/12/4EA; Aluminium Sliding Window DG 4/8/4ET; Sliding Door DG 6.38CPClr/8/4 and 1 more types
Wall insulation
R3.0
Roof and ceiling insulation
Ceiling R6.0, roof Cont:Attic-Continuous 1.3, medium colour
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by S4 Constructions.

BASIX certificate

Energy score
80 (target 70)
Water score
44 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
36 MJ/m² a year
Cooling load
23 MJ/m² a year
Bedrooms
4
Conditioned floor area
310 m²
Unconditioned floor area
12 m²
Site area
756 m²
Roof area
368 m²
Garden area
50 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
6 kW
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
aluminium frames 80 m², double glazing 80 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - untreated softwood. all external walls fibreglass batts or roll+ foil/sarking
  • External garage wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll+ foil/sarking)
  • Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1798541S_02, issued 14 August 2025, from the council's DA documents.

NatHERS certificate

Star rating
7.1 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
14 Aug 2025
Wall insulation
R3.0
Ceiling insulation
R6.0
Floor insulation
R2.0, R3.0, R2.5
Living room glazing by direction
N 18.6 m², E 21.5 m², S 7.2 m², W 9.3 m²
All glazing by direction
N 26 m², E 30.7 m², S 11.9 m², W 19.3 m²

Roof

  • Cont:Attic-Continuous 1.3, medium colour

Window types

  • DOW-005-02 A Manor Awning Window DG 4/12/4EA: U-value 3.41, SHGC 0.52
  • DOW-018-02 A Aluminium Sliding Window DG 4/8/4ET: U-value 3.66, SHGC 0.58
  • DOW-007-06 A Sliding Door DG 6.38CPClr/8/4: U-value 3.59, SHGC 0.5
  • DOW-015-01 A Aluminium Fixed Light Window DG 4/12/4: U-value 3.59, SHGC 0.66

Window schedule

  • Bedroom 3, window DOW-005-02 A: 2,100 × 610 mm facing W
  • Bedroom 3, window DOW-005-02 A: 2,100 × 610 mm facing W
  • Ensuite 3, window DOW-018-02 A: 1,200 × 610 mm facing W
  • Ensuite 2, window DOW-018-02 A: 1,200 × 610 mm facing W
  • Bedroom 2, window DOW-005-02 A: 2,100 × 610 mm facing W
  • Bedroom 2, window DOW-005-02 A: 2,100 × 610 mm facing W
  • Laundry, window DOW-005-02 A: 2,400 × 820 mm facing W
  • Ensuite, window DOW-018-02 A: 1,200 × 610 mm facing W
  • Ensuite, window DOW-018-02 A: 1,200 × 610 mm facing W
  • Master Bedroom, window DOW-007-06 A: 2,700 × 1,810 mm facing E
  • Master Bedroom, window DOW-018-02 A: 2,100 × 2,650 mm facing N
  • Powder, window DOW-018-02 A: 600 × 1,210 mm facing E
  • Pooja/Study, window DOW-005-02 A: 2,100 × 850 mm facing E
  • Pooja/Study, window DOW-005-02 A: 2,100 × 850 mm facing E
  • Butler's Kitchen, window DOW-018-02 A: 700 × 1,800 mm facing E
  • Guest Bedroom, window DOW-005-02 A: 2,560 × 1,810 mm facing S
  • Entry/Living, window DOW-015-01 A: 2,400 × 3,010 mm facing N
  • Kitchen/Living/-Dining, window DOW-018-02 A: 1,500 × 2,650 mm facing E
  • Kitchen/Living/-Dining, window DOW-018-02 A: 1,500 × 2,650 mm facing E
  • Kitchen/Living/-Dining, window DOW-015-01 A: 600 × 3,450 mm facing N
  • Kitchen/Living/-Dining, window DOW-007-06 A: 2,700 × 3,450 mm facing N
  • Kitchen/Living/-Dining, window DOW-007-06 A: 2,700 × 3,450 mm facing E
  • Kitchen/Living/-Dining, window DOW-015-01 A: 730 × 4,000 mm facing E
  • Kitchen/Living/-Dining, window DOW-015-01 A: 2,400 × 3,010 mm facing S
  • Kitchen/Living/-Dining, window DOW-007-06 A: 2,700 × 3,450 mm facing W
  • Theatre, window DOW-015-01 A: 600 × 3,010 mm facing N

Certificate BWL4Z73GMR-01, issued 14 August 2025, from the council's DA documents. Verify this certificate

Other certificates for this address

BASIX certificate, certificate 1798541S, issued 4 June 2025

BASIX certificate

Energy score
80 (target 70)
Water score
44 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
36 MJ/m² a year
Cooling load
22 MJ/m² a year
Bedrooms
4
Conditioned floor area
310 m²
Unconditioned floor area
12 m²
Site area
756 m²
Roof area
368 m²
Garden area
50 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
6 kW
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
aluminium frames 80 m², double glazing 80 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - untreated softwood. all external walls fibreglass batts or roll+ foil/sarking
  • External garage wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll+ foil/sarking)
  • Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1798541S, issued 4 June 2025, from the council's DA documents.

NatHERS certificate, certificate BWL4Z73GMR, issued 3 June 2025

NatHERS certificate

Star rating
7.1 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
3 Jun 2025
Wall insulation
R3.0
Ceiling insulation
R6.0
Floor insulation
R2.0, R3.0, R2.5
Living room glazing by direction
N 18.6 m², E 21.5 m², S 7.2 m², W 9.3 m²
All glazing by direction
N 26 m², E 30.7 m², S 11.9 m², W 18.1 m²

Roof

  • Cont:Attic-Continuous 1.3, medium colour

Window types

  • DOW-005-02 A Manor Awning Window DG 4/12/4EA: U-value 3.41, SHGC 0.52
  • DOW-018-02 A Aluminium Sliding Window DG 4/8/4ET: U-value 3.66, SHGC 0.58
  • DOW-007-06 A Sliding Door DG 6.38CPClr/8/4: U-value 3.59, SHGC 0.5
  • DOW-015-01 A Aluminium Fixed Light Window DG 4/12/4: U-value 3.59, SHGC 0.66

Window schedule

  • Bedroom 3, window DOW-005-02 A: 2,100 × 610 mm facing W
  • Ensuite 3, window DOW-018-02 A: 1,200 × 610 mm facing W
  • Ensuite 2, window DOW-018-02 A: 1,200 × 610 mm facing W
  • Bedroom 2, window DOW-005-02 A: 2,100 × 610 mm facing W
  • Bedroom 2, window DOW-005-02 A: 2,100 × 610 mm facing W
  • Laundry, window DOW-005-02 A: 2,400 × 820 mm facing W
  • Ensuite, window DOW-018-02 A: 1,200 × 610 mm facing W
  • Ensuite, window DOW-018-02 A: 1,200 × 610 mm facing W
  • Master Bedroom, window DOW-007-06 A: 2,700 × 1,810 mm facing E
  • Master Bedroom, window DOW-018-02 A: 2,100 × 2,650 mm facing N
  • Powder, window DOW-018-02 A: 600 × 1,210 mm facing E
  • Pooja/Study, window DOW-005-02 A: 2,100 × 850 mm facing E
  • Pooja/Study, window DOW-005-02 A: 2,100 × 850 mm facing E
  • Butler's Kitchen, window DOW-018-02 A: 700 × 1,800 mm facing E
  • Guest Bedroom, window DOW-005-02 A: 2,560 × 1,810 mm facing S
  • Entry/Living, window DOW-015-01 A: 2,400 × 3,010 mm facing N
  • Kitchen/Living/-Dining, window DOW-018-02 A: 1,500 × 2,650 mm facing E
  • Kitchen/Living/-Dining, window DOW-018-02 A: 1,500 × 2,650 mm facing E
  • Kitchen/Living/-Dining, window DOW-015-01 A: 600 × 3,450 mm facing N
  • Kitchen/Living/-Dining, window DOW-007-06 A: 2,700 × 3,450 mm facing N
  • Kitchen/Living/-Dining, window DOW-007-06 A: 2,700 × 3,450 mm facing E
  • Kitchen/Living/-Dining, window DOW-015-01 A: 730 × 4,000 mm facing E
  • Kitchen/Living/-Dining, window DOW-015-01 A: 2,400 × 3,010 mm facing S
  • Kitchen/Living/-Dining, window DOW-007-06 A: 2,700 × 3,450 mm facing W
  • Theatre, window DOW-015-01 A: 600 × 3,010 mm facing N

Certificate BWL4Z73GMR, issued 3 June 2025, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.