North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
47 Corvus Way Box Hill NSW 2765
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 3.7 kW of solar panels and a 3,000 litre rainwater tank. It beat its BASIX energy target, scoring 90 against 70.
Key features
- Windows
- Up to aluminium frames 42.5 m², double glazing 42.5 m²
- Wall insulation
- All external walls fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil/sarking
- Hot water
- Gas instantaneous with a performance of 5 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Meridian Homes.
BASIX certificate
- Energy score
- 90 (target 70)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -69
- Heating load
- 32 MJ/m² a year
- Cooling load
- 27 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 178.6 m²
- Unconditioned floor area
- 19.6 m²
- Site area
- 300 m²
- Roof area
- 164 m²
- Garden area
- 119 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 5 stars
- Solar panels
- 3.7 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 42.5 m², double glazing 42.5 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (not specified)
- Floor: suspended floor above open subfloor, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (not specified)
- External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (not specified)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1764352S_02, issued 12 February 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- FirstRate5: 5.5.5a (3.22)
- Rated on
- 12 Feb 2025
Certificate 1R495220NV-01, issued 12 February 2025, from the council's DA documents. Verify this certificate
Other certificates for this address
BASIX certificate, certificate 1764352S, issued 13 September 2024
BASIX certificate
- Energy score
- 90 (target 70)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -69
- Heating load
- 32 MJ/m² a year
- Cooling load
- 27 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 178.6 m²
- Unconditioned floor area
- 19.6 m²
- Site area
- 300 m²
- Roof area
- 164 m²
- Garden area
- 119 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 5 stars
- Solar panels
- 3.7 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 42.5 m², double glazing 42.5 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (not specified)
- Floor: suspended floor above open subfloor, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (not specified)
- External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (not specified)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1764352S, issued 13 September 2024, from the council's DA documents.
NatHERS certificate, certificate 1R495220NV, issued 16 August 2024
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- FirstRate5: 5.5.5 (3.22)
- Rated on
- 16 Aug 2024
Certificate 1R495220NV, issued 16 August 2024, from the council's DA documents. Verify this certificate
Is this your home? Ask us to remove these details.