North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
47 Almandin Street Gables NSW 2765
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 3 kW of solar panels. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 75 against 70 for energy and 46 against 40 for water.
Key features
- Windows
- 29 windows and glazed doors
- Wall insulation
- R2.5
- Roof and ceiling insulation
- Ceiling R2.5, R5, roof Waterproofing Membrane No Insulation, Only an Air Gap, medium colour
- Hot water
- Gas instantaneous with a performance of 5 stars
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 75 (target 70)
- Water score
- 46 (target 40)
- Thermal performance
- Pass
- Materials score
- -77
- Heating load
- 41 MJ/m² a year
- Cooling load
- 18 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 326.3 m²
- Unconditioned floor area
- 17.4 m²
- Site area
- 621 m²
- Roof area
- 336 m²
- Garden area
- 190 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 5 stars
- Solar panels
- 3 kW
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 105.5 m², double glazing 105.5 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1805443S_03, issued 22 August 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- BERS Pro v5.2.4 (3.23)
- Rated on
- 24 Jul 2025
- Wall insulation
- R2.5
- Ceiling insulation
- R2.5, R5
- Floor insulation
- R2.5
- LED downlights
- 142
- Living room glazing by direction
- NE 5.8 m², SE 5.8 m²
- All glazing by direction
- NE 29.2 m², SE 40.6 m², SW 26 m², NW 9.7 m²
Roof
- Waterproofing Membrane No Insulation, Only an Air Gap, medium colour
- Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R2, medium colour
- Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
- Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, dark colour
Window schedule
- Garage-GF AWS-003-008-001 W.11: 600 × 1,210 mm facing NW
- Lounge-GF AWS-067-009-001 W.01: 2,400 × 2,410 mm facing NE
- Lounge-GF AWS-008-008-001 W.02: 2,400 × 2,410 mm facing SE
- Theatre-GF AWS-008-008-001 W.03: 600 × 3,000 mm facing SE
- Guest-GF AWS-003-008-001 W.10: 600 × 1,810 mm facing NW
- Entry-GF AWS-019-003-001 D.01: 2,700 × 1,840 mm facing NE
- Pantry-GF AWS-003-008-001 W.09: 600 × 1,210 mm facing NW
- Ktch/Mls-GF AWS-067-051-001 W.06: 2,500 × 2,250 mm facing SE
- Ktch/Mls-GF AWS-067-051-001 W.07: 2,500 × 3,950 mm facing SW
- Ktch/Mls-GF AWS-067-051-001 W.08: 600 × 4,500 mm facing NW
- Fam/Stairs-GF AWS-017-061-001 D.02: 2,700 × 4,620 mm facing SW
- Fam/Stairs-GF AWS-008-008-001 W.04: 1,750 × 1,810 mm facing SE
- Fam/Stairs-GF AWS-008-008-001 W.05: 1,750 × 1,810 mm facing SE
- Fam/Stairs-GF AWS-067-009-001 W.05: 1,250 × 1,810 mm facing SE
- Fam/Stairs-GF AWS-067-009-001 W.04: 1,250 × 1,810 mm facing SE
- Sitting-FF AWS-067-051-001 W.15: 2,048 × 2,371 mm facing NE
- Sitting-FF AWS-013-061-001 D.05: 2,100 × 2,910 mm facing SE
- Void-FF AWS-067-051-001 W.14: 2,340 × 1,900 mm facing NE
- Void-FF AWS-067-009-001 W.04: 2,145 × 1,810 mm facing SE
- Void-FF AWS-067-009-001 W.05: 2,145 × 1,810 mm facing SE
- Bedroom 3-FF AWS-003-074-001 W.17: 1,000 × 1,810 mm facing SW
- Bedroom 2-FF AWS-003-074-001 W.18: 1,000 × 1,810 mm facing SW
- Bedroom 2-FF AWS-003-074-001 W.19: 1,000 × 1,810 mm facing NW
- Bath-FF AWS-003-074-001 W.20: 1,000 × 1,210 mm facing NW
- Master Bed-FF AWS-067-051-001 W.12: 1,355 × 520 mm facing NW
- Master Bed-FF AWS-067-051-001 W.13: 1,355 × 1,600 mm facing NE
- Master Bed-FF AWS-013-061-001 D.04: 2,400 × 2,910 mm facing NE
- Ens/M.Bed-FF AWS-003-074-001 W.21: 1,000 × 750 mm facing NW
- Bedroom 4-FF AWS-008-064-001 W.16: 900 × 3,000 mm facing SE
Certificate 0012073375, issued 24 July 2025, from the council's DA documents. Verify this certificate
Other certificates for this address
BASIX certificate, certificate 1805443S_02, issued 24 July 2025
BASIX certificate
- Energy score
- 75 (target 70)
- Water score
- 41 (target 40)
- Thermal performance
- Pass
- Materials score
- -77
- Heating load
- 41 MJ/m² a year
- Cooling load
- 18 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 326.3 m²
- Unconditioned floor area
- 17.4 m²
- Site area
- 621 m²
- Roof area
- 336 m²
- Garden area
- 190 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 5 stars
- Solar panels
- 3 kW
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 105.5 m², double glazing 105.5 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1805443S_02, issued 24 July 2025, from the council's DA documents.
Is this your home? Ask us to remove these details.