Skip to main content

45 Jaffa Road Dural NSW 2158

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to 1 kW of solar panels and a 3,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 72 against 70 for energy and 42 against 40 for water.

Key features

Windows
Up to aluminium frames 113.5 m², timber frames 3.8 m², single glazing 20.8 m², double glazing 96.5 m²
Wall insulation
All external walls fibreglass batts or roll
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Gas instantaneous with a performance of 5 stars
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

BASIX certificate

Energy score
72 (target 70)
Water score
42 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
29 MJ/m² a year
Cooling load
30 MJ/m² a year
Bedrooms
4
Conditioned floor area
410.7 m²
Unconditioned floor area
7.7 m²
Site area
697 m²
Roof area
314 m²
Garden area
283 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 5 stars
Solar panels
1 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 113.5 m², timber frames 3.8 m², single glazing 20.8 m², double glazing 96.5 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (not specified)
  • Floor: above habitable rooms or mezzanine, AAC panel (75 mm); frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, AAC panel (75 mm); frame: timber - H2 treated softwood (no added insulation)
  • Garage floor: concrete slab on ground (not specified)
  • External wall: AAC veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
  • External garage wall: AAC veneer; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1743592S_04, issued 18 October 2024, from the council's DA documents.

NatHERS certificate

Star rating
7.1 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
18 Oct 2024

Certificate G93NR53XZX-02, issued 18 October 2024, from the council's DA documents. Verify this certificate

Other certificates for this address

BASIX certificate, certificate 1743592S, issued 15 April 2024

BASIX certificate

Energy score
72 (target 70)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
29 MJ/m² a year
Cooling load
31 MJ/m² a year
Bedrooms
3
Conditioned floor area
410.7 m²
Unconditioned floor area
7.7 m²
Site area
697 m²
Roof area
314 m²
Garden area
297 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 5 stars
Solar panels
1 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 113.5 m², timber frames 3.8 m², single glazing 20.8 m², double glazing 96.5 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (not specified)
  • Floor: above habitable rooms or mezzanine, AAC panel (75 mm); frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, AAC panel (75 mm); frame: timber - H2 treated softwood (no added insulation)
  • Garage floor: concrete slab on ground (not specified)
  • External wall: AAC veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
  • External garage wall: AAC veneer; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1743592S, issued 15 April 2024, from the council's DA documents.

NatHERS certificate, certificate G93NR53XZX, issued 10 April 2024

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.4 (3.22)
Rated on
10 Apr 2024

Certificate G93NR53XZX, issued 10 April 2024, from the council's DA documents. Verify this certificate