40 Aplite Circuit Gables NSW 2765
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 1.76 kW of solar panels. It beat its BASIX energy and water targets, scoring 77 against 70 for energy and 50 against 40 for water.
Key features
- Windows
- Up to aluminium frames 111.4 m², single glazing 111.4 m²
- Wall insulation
- All external walls fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 77 (target 70)
- Water score
- 50 (target 40)
- Thermal performance
- Pass
- Materials score
- -85
- Heating load
- 31 MJ/m² a year
- Cooling load
- 28 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 461.4 m²
- Unconditioned floor area
- 18.8 m²
- Site area
- 721 m²
- Roof area
- 397 m²
- Garden area
- 294 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 1.76 kW
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 6 star, basin taps 6 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 111.4 m², single glazing 111.4 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (polystyrene)
- Floor: above habitable rooms or mezzanine, fibre cement; frame: timber - untreated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, fibre cement; frame: timber - untreated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (polystyrene)
- External wall: brick veneer; frame: timber - untreated softwood. all external walls fibreglass batts or roll+ foil/sarking
- External garage wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1779205S_04, issued 1 April 2025, from the council's DA documents.
Other certificates for this address
BASIX certificate, certificate 1779205S_03, issued 27 March 2025
BASIX certificate
- Energy score
- 77 (target 70)
- Water score
- 50 (target 40)
- Thermal performance
- Pass
- Materials score
- -85
- Heating load
- 31 MJ/m² a year
- Cooling load
- 28 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 461.4 m²
- Unconditioned floor area
- 18.8 m²
- Site area
- 721 m²
- Roof area
- 397 m²
- Garden area
- 294 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 1.76 kW
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 6 star, basin taps 6 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 111.4 m², single glazing 111.4 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (polystyrene)
- Floor: above habitable rooms or mezzanine, fibre cement; frame: timber - untreated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, fibre cement; frame: timber - untreated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (polystyrene)
- External wall: brick veneer; frame: timber - untreated softwood. all external walls fibreglass batts or roll+ foil/sarking
- External garage wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1779205S_03, issued 27 March 2025, from the council's DA documents.
BASIX certificate, certificate 1779205S_02, issued 30 December 2024
BASIX certificate
- Energy score
- 77 (target 70)
- Water score
- 50 (target 40)
- Thermal performance
- Pass
- Materials score
- -85
- Heating load
- 31 MJ/m² a year
- Cooling load
- 28 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 461.4 m²
- Unconditioned floor area
- 18.8 m²
- Site area
- 721 m²
- Roof area
- 397 m²
- Garden area
- 294 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 1.76 kW
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 6 star, basin taps 6 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 111.4 m², single glazing 111.4 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (polystyrene)
- Floor: above habitable rooms or mezzanine, fibre cement; frame: timber - untreated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, fibre cement; frame: timber - untreated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (polystyrene)
- External wall: brick veneer; frame: timber - untreated softwood. all external walls fibreglass batts or roll+ foil/sarking
- External garage wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1779205S_02, issued 30 December 2024, from the council's DA documents.