4 Wayfarer Road Gables NSW 2765

BASIX certificate and NatHERS rating

Finding the block on the map…

This home's BASIX certificate commits it to 10 kW of solar panels. It beat its BASIX energy and water targets, scoring 100 against 70 for energy and 53 against 40 for water.

Key features

Windows
Up to aluminium frames 105.3 m², timber frames 2 m², single glazing 2 m², double glazing 105.3 m²
Wall insulation
Fibreglass batts or roll
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

Built by A-team Building Group.

BASIX certificate

Energy score
100 (target 70)
Water score
53 (target 40)
Thermal performance
Pass
Materials score
-86
Heating load
35 MJ/m² a year
Cooling load
22 MJ/m² a year
Bedrooms
6
Conditioned floor area
313.1 m²
Unconditioned floor area
19.3 m²
Site area
712 m²
Roof area
326 m²
Garden area
294 m²
Climate zone
NatHERS climate zone 28
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Solar panels
10 kW
Fixtures
Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 105.3 m², timber frames 2 m², single glazing 2 m², double glazing 105.3 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: suspended floor above open subfloor, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, AAC panel (75 mm); frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
  • External garage wall: cavity brick; frame: no frame (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1824141S_03, issued 4 February 2026, from the council's DA documents.

Other certificates for this address

BASIX certificate, certificate 1824141S_02, issued 17 December 2025

BASIX certificate

Energy score
100 (target 70)
Water score
50 (target 40)
Thermal performance
Pass
Materials score
-86
Heating load
35 MJ/m² a year
Cooling load
22 MJ/m² a year
Bedrooms
6
Conditioned floor area
313.1 m²
Unconditioned floor area
19.3 m²
Site area
712 m²
Roof area
326 m²
Garden area
294 m²
Climate zone
NatHERS climate zone 28
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Solar panels
10 kW
Fixtures
Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 105.3 m², timber frames 2 m², single glazing 2 m², double glazing 105.3 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: suspended floor above open subfloor, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, AAC panel (75 mm); frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
  • External garage wall: cavity brick; frame: no frame (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1824141S_02, issued 17 December 2025, from the council's DA documents.