4 Mandalas Street Gables NSW 2765
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 1.5 kW of solar panels and a 24,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 75 against 70 for energy and 56 against 40 for water.
Key features
- Windows
- Up to aluminium frames 130.4 m², single glazing 2.3 m², double glazing 128.1 m²
- Wall insulation
- All external walls fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
Built by Kurmond Homes.
BASIX certificate
- Energy score
- 75 (target 70)
- Water score
- 56 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 34 MJ/m² a year
- Cooling load
- 26 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 436.2 m²
- Unconditioned floor area
- 37 m²
- Site area
- 20,000 m²
- Roof area
- 784 m²
- Garden area
- 500 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 1.5 kW
- Rainwater tank
- 24,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 130.4 m², single glazing 2.3 m², double glazing 128.1 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- External garage wall: brick veneer; frame: timber - untreated softwood (no added insulation)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1766330S_03, issued 18 December 2024, from the council's DA documents.
Other certificates for this address
BASIX certificate, certificate 1766330S_02, issued 1 November 2024
BASIX certificate
- Energy score
- 75 (target 70)
- Water score
- 56 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 34 MJ/m² a year
- Cooling load
- 26 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 436.2 m²
- Unconditioned floor area
- 37 m²
- Site area
- 20,000 m²
- Roof area
- 784 m²
- Garden area
- 500 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 1.5 kW
- Rainwater tank
- 24,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 130.4 m², single glazing 2.3 m², double glazing 128.1 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- External garage wall: brick veneer; frame: timber - untreated softwood (no added insulation)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1766330S_02, issued 1 November 2024, from the council's DA documents.
BASIX certificate, certificate 1766330S, issued 26 September 2024
BASIX certificate
- Energy score
- 75 (target 70)
- Water score
- 56 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 34 MJ/m² a year
- Cooling load
- 26 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 436.2 m²
- Unconditioned floor area
- 37 m²
- Site area
- 20,000 m²
- Roof area
- 784 m²
- Garden area
- 500 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 1.5 kW
- Rainwater tank
- 24,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 130.4 m², single glazing 2.3 m², double glazing 128.1 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- External garage wall: brick veneer; frame: timber - untreated softwood (no added insulation)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1766330S, issued 26 September 2024, from the council's DA documents.
Is this your home? Ask us to remove these details.