North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
4 Hinterland Place Cattai NSW 2756
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to a 3,000 litre rainwater tank. It beat its BASIX water target, scoring 41 against 40.
Key features
- Windows
- Up to aluminium frames 85.1 m², single glazing 54.8 m², double glazing 30.3 m²
- Wall insulation
- Fibreglass batts or roll+ foil/sarking; Rockwool batts, roll or pump-in+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, non ducted (living area); 1-phase airconditioning, ducted (bedroom and living area)
Built by Clarendon Homes.
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 41 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 33 MJ/m² a year
- Cooling load
- 27 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 375 m²
- Unconditioned floor area
- 17.2 m²
- Site area
- 4,000 m²
- Roof area
- 486 m²
- Garden area
- 597 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 85.1 m², single glazing 54.8 m², double glazing 30.3 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 3.5 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3.5 star (average zone)
Cooling
- Living area: 1-phase airconditioning - non ducted; Energy rating: 3 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (not specified)
- Floor: above habitable rooms or mezzanine, particle board; frame: light steel frame (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (not specified)
- External wall: AAC veneer; frame: light steel frame (fibreglass batts or roll+ foil/sarking)
- External wall: framed (solid or reconstituted timber weatherboard); frame: light steel frame (rockwool batts, roll or pump-in+ foil/sarking)
- External garage wall: AAC veneer; frame: light steel frame (no added insulation)
- Internal wall: plasterboard; frame: light steel frame (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1737661S_02, issued 17 July 2024, from the council's DA documents.
Is this your home? Ask us to remove these details.