Skip to main content

35 Roland Garros Crescent North Kellyville NSW 2155

BASIX certificate and NatHERS rating

Finding the block on the map…

This home's BASIX certificate commits it to a 4,200 litre rainwater tank. It beat its BASIX water target, scoring 47 against 40.

Key features

Windows
Up to aluminium frames 54.4 m², single glazing 50.5 m², double glazing 3.9 m²
Wall insulation
Fibreglass batts or roll+ foil/sarking
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil/sarking
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by Clarendon Homes.

BASIX certificate

Energy score
70 (target 70)
Water score
47 (target 40)
Thermal performance
Pass
Materials score
-61
Heating load
37 MJ/m² a year
Cooling load
23 MJ/m² a year
Bedrooms
5
Conditioned floor area
285.2 m²
Unconditioned floor area
10 m²
Site area
600 m²
Roof area
285 m²
Garden area
286 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 6 stars
Rainwater tank
4,200 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 54.4 m², single glazing 50.5 m², double glazing 3.9 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3.5 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3.5 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: suspended floor above open subfloor, particle board; frame: light steel frame (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, particle board; frame: light steel frame (fibreglass batts or roll)
  • Floor: suspended floor above garage, particle board; frame: light steel frame (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: light steel frame (fibreglass batts or roll+ foil/sarking)
  • External wall: framed (fibre cement sheet or boards); frame: light steel frame (fibreglass batts or roll+ foil/sarking)
  • External garage wall: brick veneer; frame: light steel frame (no added insulation)
  • External garage wall: cavity brick; frame: no frame (no added insulation)
  • Internal wall: plasterboard; frame: light steel frame (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1800272S, issued 18 June 2025, from the council's DA documents.