North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
35 Roland Garros Crescent North Kellyville NSW 2155
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to a 4,200 litre rainwater tank. It beat its BASIX water target, scoring 47 against 40.
Key features
- Windows
- Up to aluminium frames 54.4 m², single glazing 50.5 m², double glazing 3.9 m²
- Wall insulation
- Fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil/sarking
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Clarendon Homes.
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 47 (target 40)
- Thermal performance
- Pass
- Materials score
- -61
- Heating load
- 37 MJ/m² a year
- Cooling load
- 23 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 285.2 m²
- Unconditioned floor area
- 10 m²
- Site area
- 600 m²
- Roof area
- 285 m²
- Garden area
- 286 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Rainwater tank
- 4,200 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 54.4 m², single glazing 50.5 m², double glazing 3.9 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 3.5 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3.5 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: suspended floor above open subfloor, particle board; frame: light steel frame (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, particle board; frame: light steel frame (fibreglass batts or roll)
- Floor: suspended floor above garage, particle board; frame: light steel frame (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: light steel frame (fibreglass batts or roll+ foil/sarking)
- External wall: framed (fibre cement sheet or boards); frame: light steel frame (fibreglass batts or roll+ foil/sarking)
- External garage wall: brick veneer; frame: light steel frame (no added insulation)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: light steel frame (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1800272S, issued 18 June 2025, from the council's DA documents.