North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
35 Almandin Street Gables NSW 2765
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 5.1 stars out of 10. Its BASIX certificate commits it to 1 kW of solar panels. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 51 against 50 for energy and 47 against 40 for water.
Key features
- Windows
- 30 windows and glazed doors: Timber A SG Clear; Timber B SG Clear; 516 Al Awining Window SG 6.38Sct and 7 more types
- Wall insulation
- R2.5
- Roof and ceiling insulation
- Ceiling R2.5, R4, roof Waterproofing Membrane No Insulation, Only an Air Gap, medium colour
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
Built by Woodcastle Homes.
BASIX certificate
- Energy score
- 51 (target 50)
- Water score
- 47 (target 40)
- Thermal performance
- Pass
- Heating load
- 54 MJ/m² a year
- Cooling load
- 54 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 295 m²
- Unconditioned floor area
- 16 m²
- Site area
- 450 m²
- Roof area
- 265 m²
- Garden area
- 158 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 1 kW
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Certificate 1342554S, issued 23 September 2022, from the council's DA documents.
NatHERS certificate
- Star rating
- 5.1 stars
- Rated with
- BERS Pro v4.4.1.5 (3.21)
- Rated on
- 23 Sep 2022
- Wall insulation
- R2.5
- Ceiling insulation
- R2.5, R4
- Floor insulation
- R2.5
- LED downlights
- 131
- All glazing by direction
- N 37.9 m², E 10.5 m², S 33.8 m², W 31.1 m²
Roof
- Waterproofing Membrane No Insulation, Only an Air Gap, medium colour
- Corrugated Iron Bulk, Reflective Side Down, No Air Gap Above R1.3, dark colour
Window types
- TIM-001-01 W Timber A SG Clear: U-value 5.4, SHGC 0.56
- TIM-002-01 W Timber B SG Clear: U-value 5.4, SHGC 0.63
- AWS-007-06 A 516 Al Awining Window SG 6.38Sct: U-value 4.9, SHGC 0.53
- AWS-066-08 A RES SERIES 516 FIXED WINDOW SG 5mmEnTech: U-value 4, SHGC 0.64
- AWS-067-07 A RES SERIES 516 FIXED WINDOW DG 4mmClr-10Ar-4mmEnTech: U-value 2.4, SHGC 0.64
- AWS-013-03 A 541/542 Al Sliding Door DG 4/10Ar/4ET: U-value 3.2, SHGC 0.57
- AWS-008-03 A 516 Al Awining Window DG 4/10Ar/4ET: U-value 3.6, SHGC 0.52
- AWS-011-05 A 541/542 Al Sliding Door SG 6.38Sct: U-value 4.4, SHGC 0.59
- AWS-071-33 A RES SERIES 616 FIXED WINDOW DG 4mmLoE-366-12Ar-4mmClr: U-value 2.7, SHGC 0.25
- AWS-008-10 A 516 Al Awining Window DG 4SnClr/10Ar/4: U-value 3.8, SHGC 0.4
Window schedule
- Theatre-GF, window AWS-007-06 A: 600 × 1,810 mm facing E
- Wip-GF, window AWS-066-08 A: 600 × 3,000 mm facing E
- Ldry-GF, window AWS-066-08 A: 600 × 1,570 mm facing E
- Ktch/Fam/Mls, window AWS-067-07 A: 2,730 × 4,000 mm facing S
- Ktch/Fam/Mls, window AWS-013-03 A: 2,400 × 3,830 mm facing W
- Ktch/Fam/Mls, window AWS-013-03 A: 2,400 × 2,770 mm facing S
- Ktch/Fam/Mls, window AWS-008-03 A: 2,340 × 1,000 mm facing W
- Ktch/Fam/Mls, window AWS-008-03 A: 2,340 × 1,000 mm facing W
- Ktch/Fam/Mls, window AWS-008-03 A: 2,340 × 1,810 mm facing N
- Entry/St-GF, window AWS-013-03 A: 2,400 × 3,000 mm facing W
- Entry/St-GF, window TIM-001-01 W: 2,700 × 1,500 mm facing N
- Entry/St-GF, window TIM-002-01 W: 2,700 × 200 mm facing N
- Guest-GF, window AWS-007-06 A: 2,100 × 2,410 mm facing N
- Ens/Guest-GF, window AWS-007-06 A: 600 × 850 mm facing S
- M.Bed-FF, window AWS-007-06 A: 940 × 2,170 mm facing E
- M.Bed-FF, window AWS-011-05 A: 2,400 × 3,610 mm facing N
- Ens/M.Bed-FF, window AWS-007-06 A: 860 × 1,210 mm facing E
- Bath-FF, window AWS-007-06 A: 860 × 1,210 mm facing E
- Bed 2-FF, window AWS-007-06 A: 940 × 1,810 mm facing E
- Ens/Bed 2-FF, window AWS-007-06 A: 860 × 1,000 mm facing E
- Void/Fam-FF, window AWS-067-07 A: 2,400 × 4,000 mm facing S
- Bed 3-FF, window AWS-007-06 A: 940 × 2,410 mm facing S
- Bed 4-FF, window AWS-007-06 A: 940 × 1,810 mm facing W
- Bed 4-FF, window AWS-066-08 A: 2,100 × 1,810 mm facing N
- Sitt/St-FF, window AWS-071-33 A: 2,400 × 3,000 mm facing W
- Sitt/St-FF, window AWS-067-07 A: 2,100 × 1,810 mm facing S
- Sitt/St-FF, window AWS-007-06 A: 600 × 1,810 mm facing W
- Sitt/St-FF, window AWS-008-10 A: 2,100 × 2,410 mm facing N
- Sitt/St-FF, window AWS-071-33 A: 2,400 × 1,860 mm facing N
- Sitt/St-FF, window AWS-071-33 A: 2,100 × 970 mm facing N
Certificate 0008084543, issued 23 September 2022, from the council's DA documents. Verify this certificate