North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
33 Sovite Street Gables NSW 2765
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to 1.5 kW of solar panels. It beat its BASIX water target, scoring 51 against 40.
Key features
- Windows
- Up to timber frames 117.6 m², double glazing 117.6 m²
- Wall insulation
- Polystyrene; Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 5 stars
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 51 (target 40)
- Thermal performance
- Pass
- Materials score
- -49
- Heating load
- 37 MJ/m² a year
- Cooling load
- 22 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 317.8 m²
- Unconditioned floor area
- 18.2 m²
- Site area
- 733 m²
- Roof area
- 371 m²
- Garden area
- 232 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 5 stars
- Solar panels
- 1.5 kW
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Maximum glazing
- timber frames 117.6 m², double glazing 117.6 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Construction and insulation
- Floor: concrete slab on ground, conventional slab (polystyrene)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (polystyrene)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: cavity brick; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1766079S_02, issued 10 December 2024, from the council's DA documents.
Other certificates for this address
BASIX certificate, certificate 1766079S, issued 25 September 2024
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 51 (target 40)
- Thermal performance
- Pass
- Materials score
- -49
- Heating load
- 36 MJ/m² a year
- Cooling load
- 24 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 317.8 m²
- Unconditioned floor area
- 18.2 m²
- Site area
- 733 m²
- Roof area
- 371 m²
- Garden area
- 232 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 5 stars
- Solar panels
- 1.5 kW
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Maximum glazing
- timber frames 117.6 m², double glazing 117.6 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Construction and insulation
- Floor: concrete slab on ground, conventional slab (polystyrene)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (polystyrene)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: cavity brick; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1766079S, issued 25 September 2024, from the council's DA documents.
Is this your home? Ask us to remove these details.