Skip to main content

31 Celestial Street Box Hill NSW 2765

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 3,000 litre rainwater tank. It beat its BASIX water target, scoring 41 against 40.

Key features

Windows
Up to aluminium frames 38.2 m², single glazing 38.2 m²
Wall insulation
All external walls fibreglass batts or roll+ foil/sarking
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil/sarking
Hot water
Gas instantaneous with a performance of 4 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
70 (target 70)
Water score
41 (target 40)
Thermal performance
Pass
Materials score
-83
Heating load
38 MJ/m² a year
Cooling load
22 MJ/m² a year
Bedrooms
4
Conditioned floor area
134.5 m²
Unconditioned floor area
18.6 m²
Site area
250 m²
Roof area
165 m²
Garden area
67 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 4 stars
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 38.2 m², single glazing 38.2 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, 30% cement substitute, waffle pod slab (not specified)
  • Floor: suspended floor above garage, concrete - suspended; frame: timber - untreated softwood (polystyrene)
  • Garage floor: concrete slab on ground, 30% cement substitute, waffle pod slab (no added insulation)
  • External wall: AAC veneer; frame: timber - untreated softwood. all external walls fibreglass batts or roll+ foil/sarking
  • External garage wall: AAC veneer; frame: timber - untreated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1816223S_03, issued 9 April 2026, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
9 Apr 2026

Certificate A2D8H88AE2-02, issued 9 April 2026, from the council's DA documents. Verify this certificate

Other certificates for this address

BASIX certificate, certificate 1816223S_02, issued 17 December 2025

BASIX certificate

Energy score
70 (target 70)
Water score
41 (target 40)
Thermal performance
Pass
Materials score
-83
Heating load
38 MJ/m² a year
Cooling load
22 MJ/m² a year
Bedrooms
4
Conditioned floor area
134.5 m²
Unconditioned floor area
18.6 m²
Site area
250 m²
Roof area
165 m²
Garden area
67 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 4 stars
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 38.2 m², single glazing 38.2 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, 30% cement substitute, waffle pod slab (not specified)
  • Floor: suspended floor above garage, concrete - suspended; frame: timber - untreated softwood (polystyrene)
  • Garage floor: concrete slab on ground, 30% cement substitute, waffle pod slab (no added insulation)
  • External wall: AAC veneer; frame: timber - untreated softwood. all external walls fibreglass batts or roll+ foil/sarking
  • External garage wall: AAC veneer; frame: timber - untreated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1816223S_02, issued 17 December 2025, from the council's DA documents.

NatHERS certificate, certificate A2D8H88AE2-01, issued 16 December 2025

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
16 Dec 2025

Certificate A2D8H88AE2-01, issued 16 December 2025, from the council's DA documents. Verify this certificate

NatHERS certificate, certificate A2D8H88AE2, issued 8 October 2025

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
8 Oct 2025

Certificate A2D8H88AE2, issued 8 October 2025, from the council's DA documents. Verify this certificate

BASIX certificate, certificate 1816223S, issued 8 October 2025

BASIX certificate

Energy score
70 (target 70)
Water score
41 (target 40)
Thermal performance
Pass
Materials score
-71
Heating load
38 MJ/m² a year
Cooling load
22 MJ/m² a year
Bedrooms
4
Conditioned floor area
135 m²
Unconditioned floor area
18.2 m²
Site area
250 m²
Roof area
165 m²
Garden area
67 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 4 stars
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 40.8 m², single glazing 34.3 m², double glazing 6.5 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, 30% cement substitute, waffle pod slab (polystyrene)
  • Floor: suspended floor above garage, particle board; frame: timber - untreated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, 30% cement substitute, waffle pod slab (no added insulation)
  • External wall: AAC veneer; frame: timber - untreated softwood. all external walls fibreglass batts or roll+ foil/sarking
  • External garage wall: AAC veneer; frame: timber - untreated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1816223S, issued 8 October 2025, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related