Finding the block on the map…
This home's BASIX certificate commits it to 3 kW of solar panels and a 3,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 75 against 70 for energy and 41 against 40 for water.
Key features
- Windows
- Up to aluminium frames 76.5 m², double glazing 76.5 m²
- Wall insulation
- All external walls fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 75 (target 70)
- Water score
- 41 (target 40)
- Materials score
- -56
- Heating load
- 22 MJ/m² a year
- Cooling load
- 36 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 374.9 m²
- Unconditioned floor area
- 6 m²
- Site area
- 600 m²
- Roof area
- 248 m²
- Garden area
- 215 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 3 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 5 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 76.5 m², double glazing 76.5 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER < 2.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER < 2.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER < 2.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER < 2.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: suspended floor above open subfloor, treated softwood; frame: timber - H2 treated softwood (no added insulation)
- Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1857670S_02, issued 28 July 2026, from the council's DA documents.