Skip to main content

30 Halloway Boulevard North Kellyville NSW 2155

BASIX certificate and NatHERS rating

Finding the block on the map…

This home's BASIX certificate commits it to 3 kW of solar panels and a 3,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 75 against 70 for energy and 41 against 40 for water.

Key features

Windows
Up to aluminium frames 76.5 m², double glazing 76.5 m²
Wall insulation
All external walls fibreglass batts or roll
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
75 (target 70)
Water score
41 (target 40)
Materials score
-56
Heating load
22 MJ/m² a year
Cooling load
36 MJ/m² a year
Bedrooms
5
Conditioned floor area
374.9 m²
Unconditioned floor area
6 m²
Site area
600 m²
Roof area
248 m²
Garden area
215 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
3 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 5 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 76.5 m², double glazing 76.5 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER < 2.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER < 2.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER < 2.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER < 2.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: suspended floor above open subfloor, treated softwood; frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (no added insulation)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1857670S_02, issued 28 July 2026, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.