North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
29 Ernesta Place Bella Vista NSW 2153
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 5.2 stars out of 10. Its BASIX certificate commits it to 2 kW of solar panels and a 9,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 51 against 50.
Key features
- Windows
- 41 windows and glazed doors: Timber B SG Clear; Al Sliding Window SG 3Clr; Thermally Broken Aluminium Awning Window DG 4SolB/12Ar/4Clr and 6 more types
- Wall insulation
- R2.5
- Roof and ceiling insulation
- Ceiling R2.5, R5, roof Waterproofing Membrane No Insulation, Only an Air Gap, medium colour
- Hot water
- Gas instantaneous with a performance of 5 stars
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 51 (target 50)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Heating load
- 40 MJ/m² a year
- Cooling load
- 23 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 412 m²
- Unconditioned floor area
- 13 m²
- Site area
- 725 m²
- Roof area
- 336 m²
- Garden area
- 292 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 5 stars
- Solar panels
- 2 kW
- Rainwater tank
- 9,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Certificate 1169477S, issued 14 January 2021, from the council's DA documents.
NatHERS certificate
- Star rating
- 5.2 stars
- Rated with
- BERS Pro v4.4.0.2 (3.21)
- Rated on
- 14 Jan 2021
- Wall insulation
- R2.5
- Ceiling insulation
- R2.5, R5
- Floor insulation
- R2.5
- LED downlights
- 120
- Living room glazing by direction
- NE 6.5 m², SW 28.6 m², NW 10.5 m²
- All glazing by direction
- NE 47.7 m², SE 12.1 m², SW 50.4 m², NW 27 m²
Roof
- Waterproofing Membrane No Insulation, Only an Air Gap, medium colour
- Corrugated Iron Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
Window types
- TIM-002-01 W Timber B SG Clear: U-value 5.4, SHGC 0.63
- DOW-001-01 A Al Sliding Window SG 3Clr: U-value 6.4, SHGC 0.75
- DOW-021-07 B Thermally Broken Aluminium Awning Window DG 4SolB/12Ar/4Clr: U-value 1.7, SHGC 0.18
- DOW-014-06 A Aluminium Fixed Light Window SG 6.38CPNtl: U-value 4.3, SHGC 0.46
- DOW-023-06 B TB Al Fixed-DG with TPS Spacer 4SolB/12Ar/4Clr: U-value 1.6, SHGC 0.2
- DOW-022-06 B TB Aluminium Sliding Window DG 4SolB/12Ar/4Clr: U-value 1.9, SHGC 0.2
- DOW-020-05 A Aluminium Bi-Fold Door DG 6.38CPNtrl/10/4: U-value 3.6, SHGC 0.33
- DOW-005-05 A Manor Awning Window DG 6.38CP/8/4: U-value 3.6, SHGC 0.34
- DOW-025-05 B TB Aluminium Sliding Door DG 4SolB/12Ar/4Clr: U-value 1.8, SHGC 0.19
Window schedule
- Garage, window DOW-001-01 A: 500 × 2,170 mm facing SE
- Guest Bed-GF, window DOW-021-07 B: 1,500 × 2,230 mm facing SE
- Guest Bed-GF, window DOW-021-07 B: 1,500 × 610 mm facing SW
- Study-GF, window DOW-021-07 B: 3,000 × 1,345 mm facing NE
- Laundry-GF, window DOW-014-06 A: 600 × 1,210 mm facing SE
- B.Pantry-GF, window DOW-023-06 B: 600 × 2,000 mm facing SE
- B.Pantry-GF, window DOW-022-06 B: 600 × 1,570 mm facing SW
- Ktch/Din/Fam, window DOW-022-06 B: 1,800 × 1,200 mm facing SW
- Ktch/Din/Fam, window DOW-020-05 A: 2,700 × 5,460 mm facing SW
- Ktch/Din/Fam, window DOW-023-06 B: 2,600 × 1,600 mm facing SW
- Ktch/Din/Fam, window DOW-023-06 B: 2,600 × 2,900 mm facing SW
- Ktch/Din/Fam, window DOW-021-07 B: 2,100 × 850 mm facing NW
- Ktch/Din/Fam, window DOW-021-07 B: 2,100 × 850 mm facing NW
- Ktch/Din/Fam, window DOW-020-05 A: 2,400 × 2,710 mm facing NE
- Ktch/Din/Fam, window DOW-021-07 B: 2,400 × 2,900 mm facing NW
- Loun/Entry-GF, window DOW-021-07 B: 2,400 × 2,710 mm facing SW
- Loun/Entry-GF, window DOW-014-06 A: 3,680 × 1,550 mm facing NW
- Loun/Entry-GF, window DOW-023-06 B: 3,680 × 1,210 mm facing NE
- Loun/Entry-GF, window DOW-014-06 A: 3,680 × 1,250 mm facing NE
- Loun/Entry-GF, window TIM-002-01 W: 2,700 × 360 mm facing NE
- Loun/Entry-GF, window DOW-023-06 B: 980 × 1,860 mm facing NE
- Void W-FF, window DOW-023-06 B: 2,400 × 850 mm facing NW
- Void W-FF, window DOW-023-06 B: 2,400 × 850 mm facing NW
- Void W-FF, window DOW-023-06 B: 2,400 × 2,950 mm facing SW
- Bed 4-FF, window DOW-021-07 B: 1,200 × 2,170 mm facing SW
- Bath-FF, window DOW-005-05 A: 900 × 1,210 mm facing SW
- Bed 3-FF, window DOW-021-07 B: 600 × 2,230 mm facing SE
- Bed 3-FF, window DOW-021-07 B: 1,200 × 2,230 mm facing SW
- Ens/M.Bed1-FF, window DOW-005-05 A: 1,200 × 1,570 mm facing SE
- Wir/M.Bed1-FF, window DOW-014-06 A: 700 × 1,570 mm facing SE
- Master Bed1-FF, window DOW-025-05 B: 2,400 × 2,810 mm facing NE
- Master Bed1-FF, window DOW-014-06 A: 2,000 × 1,560 mm facing NE
- Master Bed1-FF, window DOW-014-06 A: 2,000 × 710 mm facing SE
- Bed 2-FF, window DOW-021-07 B: 2,100 × 1,345 mm facing NE
- Bed 2-FF, window DOW-001-01 A: 2,300 × 1,550 mm facing NW
- Void E-FF, window DOW-014-06 A: 2,300 × 1,250 mm facing NE
- Void E-FF, window DOW-023-06 B: 2,300 × 1,210 mm facing NE
- Void E-FF, window DOW-023-06 B: 2,730 × 1,860 mm facing NE
- Void E-FF, window DOW-023-06 B: 1,040 × 1,860 mm facing NE
- Void E-FF, window DOW-001-01 A: 1,800 × 850 mm facing NW
- Games-FF, window DOW-021-07 B: 1,800 × 850 mm facing NW
Certificate 0005587522-01, issued 14 January 2021, from the council's DA documents. Verify this certificate
Is this your home? Ask us to remove these details.