North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
27 Raven Road Gables NSW 2765
BASIX certificate and NatHERS rating
Finding the block on the map…
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 1 kW of solar panels. It beat its BASIX energy and water targets, scoring 84 against 70 for energy and 49 against 40 for water.
Key features
- Windows
- Up to aluminium frames 58.4 m², timber frames 1.4 m², single glazing 1.4 m², double glazing 58.4 m²
- Wall insulation
- Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil/sarking
- Hot water
- Electric heat pump with a performance of 31 to 35 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Metricon.
BASIX certificate
- Energy score
- 84 (target 70)
- Water score
- 49 (target 40)
- Thermal performance
- Pass
- Materials score
- -73
- Heating load
- 38 MJ/m² a year
- Cooling load
- 22 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 259.5 m²
- Unconditioned floor area
- 11.1 m²
- Site area
- 450 m²
- Roof area
- 256 m²
- Garden area
- 194 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Electric heat pump with a performance of 31 to 35 STCs or better
- Solar panels
- 1 kW
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 58.4 m², timber frames 1.4 m², single glazing 1.4 m², double glazing 58.4 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: suspended floor above open subfloor, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: external insulated façade system (EIFS); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1812542S_04, issued 19 December 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- FirstRate5: 5.5.5a (3.22)
- Rated on
- 19 Dec 2025
Certificate MAP43GF2G8-03, issued 19 December 2025, from the council's DA documents. Verify this certificate