Skip to main content

23 Valencia Street Dural NSW 2158

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to 1 kW of solar panels and a 3,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 74 against 70.

Key features

Windows
13 windows and glazed doors
Wall insulation
R2.5
Roof and ceiling insulation
Ceiling R6, R2, roof Roof Tiles Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, dark colour
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

Built by Elysium Group Investments.

BASIX certificate

Energy score
74 (target 70)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-92
Heating load
36 MJ/m² a year
Cooling load
22 MJ/m² a year
Bedrooms
5
Conditioned floor area
340 m²
Unconditioned floor area
26 m²
Site area
696 m²
Roof area
339 m²
Garden area
282 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
1 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 59.9 m², single glazing 59.9 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, AAC panel (75 mm); frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: AAC veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1745347S_02, issued 25 August 2024, from the council's DA documents.

NatHERS certificate

Star rating
7.1 stars
Rated with
BERS Pro v5.2.2 (3.23)
Rated on
25 Aug 2024
Wall insulation
R2.5
Ceiling insulation
R6, R2
Floor insulation
R2.5, R2
LED downlights
77
Living room glazing by direction
SE 6.3 m², SW 18.6 m²
All glazing by direction
NE 1.2 m², SE 10.8 m², SW 28.3 m², NW 2.2 m²

Roof

  • Roof Tiles Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, dark colour
  • Corrugated Iron Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, dark colour

Window schedule

  • Home Cinema STG-007-016-001: 770 × 2,650 mm facing SW
  • Kitchen/Family/ STG-073-014-001 W1: 2,100 × 3,610 mm facing SW
  • Kitchen/Family/ STG-003-009-001: 2,100 × 3,010 mm facing SE
  • Kitchen/Family/ STG-005-015-001 W2: 2,400 × 4,570 mm facing SW
  • Butlers Pantry STG-007-016-001: 600 × 2,170 mm facing SE
  • Entry STG-073-014-001 W3: 2,400 × 250 mm facing NE
  • Entry STG-073-014-001 W4: 2,400 × 250 mm facing NE
  • Bedroom 4 STG-007-016-001 W6: 1,030 × 2,650 mm facing SW
  • Master Bed STG-007-016-001 W7: 770 × 2,650 mm facing SE
  • Master Bed STG-002-019-001: 1,800 × 610 mm facing SE
  • Master Bed STG-007-016-001 W5: 1,030 × 3,010 mm facing SW
  • Ensuite STG-007-001-001: 1,030 × 1,810 mm facing SW
  • Bath STG-007-001-001: 1,200 × 1,810 mm facing NW

Certificate 0009409582-01, issued 25 August 2024, from the council's DA documents. Verify this certificate

Other certificates for this address

BASIX certificate, certificate 1745347S, issued 29 April 2024

BASIX certificate

Energy score
74 (target 70)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-71
Heating load
35 MJ/m² a year
Cooling load
25 MJ/m² a year
Bedrooms
5
Conditioned floor area
340 m²
Unconditioned floor area
26 m²
Site area
696 m²
Roof area
339 m²
Garden area
282 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
1 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 63.1 m², single glazing 63.1 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, AAC panel (75 mm); frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1745347S, issued 29 April 2024, from the council's DA documents.

NatHERS certificate, certificate 0009409582, issued 29 April 2024

NatHERS certificate

Star rating
7 stars
Rated with
BERS Pro v5.1.7 (3.22)
Rated on
29 Apr 2024
Wall insulation
R2.7
Ceiling insulation
R6, R2
Floor insulation
R2.7, R2
LED downlights
77
Living room glazing by direction
SE 6.3 m², SW 18.6 m²
All glazing by direction
NE 1.2 m², SE 10.8 m², SW 31.5 m², NW 2.2 m²

Roof

  • Roof Tiles Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, dark colour
  • Corrugated Iron Timber Frame Foil, Gap Above, Reflective Side Down, Anti-glare Up, dark colour

Window schedule

  • Home Cinema STG-007-16 A: 770 × 2,650 mm facing SW
  • Kitchen/Family/ STG-073-14 W W1: 2,100 × 3,610 mm facing SW
  • Kitchen/Family/ STG-003-09 A: 2,100 × 3,010 mm facing SE
  • Kitchen/Family/ STG-005-15 A W2: 2,400 × 4,570 mm facing SW
  • Butlers Pantry STG-007-16 A: 600 × 2,170 mm facing SE
  • Entry STG-073-14 W W3: 2,400 × 250 mm facing NE
  • Entry STG-073-14 W W4: 2,400 × 250 mm facing NE
  • Bedroom 4 STG-007-16 A: 1,030 × 2,650 mm facing SW
  • Master Bed STG-007-16 A: 770 × 2,650 mm facing SE
  • Master Bed STG-002-19 A: 1,800 × 610 mm facing SE
  • Master Bed STG-073-14 W: 2,100 × 3,010 mm facing SW
  • Ensuite STG-007-01 A: 1,030 × 1,810 mm facing SW
  • Bath STG-007-01 A: 1,200 × 1,810 mm facing NW

Certificate 0009409582, issued 29 April 2024, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.