North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
22 Wianamatta Circuit Cattai NSW 2756
BASIX certificate and NatHERS rating
Finding the block on the map…
This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to 5 kW of solar panels and a 60,000 litre rainwater tank.
Key features
- Windows
- Up to aluminium frames 143.9 m², double glazing 143.9 m²
- Wall insulation
- All external walls fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil/sarking
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 36 MJ/m² a year
- Cooling load
- 23 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 675.3 m²
- Unconditioned floor area
- 28.5 m²
- Site area
- 6,297 m²
- Roof area
- 730 m²
- Garden area
- 5,191 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 5 kW
- Rainwater tank
- 60,000 litres
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 143.9 m², double glazing 143.9 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (fibreglass batts or roll)
- Floor: suspended floor above enclosed subfloor, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
- External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1801133S_02, issued 4 November 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 7.1 stars
- Rated with
- FirstRate5: 5.5.5a (3.22)
- Rated on
- 24 Jun 2025
Certificate OTTT2FEAP3, issued 24 June 2025, from the council's DA documents. Verify this certificate
Is this your home? Ask us to remove these details.