North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
22 Doreen Crescent Baulkham Hills NSW 2153
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to a 3,000 litre rainwater tank. It beat its BASIX water target, scoring 41 against 40.
Key features
- Windows
- Up to aluminium frames 69.5 m², single glazing 15.9 m², double glazing 53.6 m²
- Wall insulation
- All external walls fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil/sarking
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 72 (target 72)
- Water score
- 41 (target 40)
- Materials score
- -100
- Heating load
- 12 MJ/m² a year
- Cooling load
- 18 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 294.2 m²
- Unconditioned floor area
- 19.7 m²
- Site area
- 702 m²
- Roof area
- 304 m²
- Garden area
- 371 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 6 stars
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 69.5 m², single glazing 15.9 m², double glazing 53.6 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 3.5 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3.5 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: above habitable rooms or mezzanine, particle board; frame: light steel frame (fibreglass batts or roll)
- Floor: suspended floor above garage, particle board; frame: light steel frame (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: AAC veneer; frame: light steel frame. all external walls fibreglass batts or roll+ foil/sarking
- External garage wall: AAC veneer; frame: light steel frame (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: light steel frame (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1841549S_02, issued 18 May 2026, from the council's DA documents.
Is this your home? Ask us to remove these details.