North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
2 Homevale Place North Kellyville NSW 2155
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 5.1 stars out of 10. Its BASIX certificate commits it to 2 kW of solar panels and a 4,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 54 against 50 for energy and 52 against 40 for water.
Key features
- Windows
- 28 windows and glazed doors: Aluminium B SG Clear; Timber A SG Clear; 502/504 Al Sliding Window SG 3Clr and 5 more types
- Wall insulation
- R2.5
- Roof and ceiling insulation
- Ceiling R2.5, R4, roof Corrugated Iron Bulk, Reflective Side Down, No Air Gap Above R1.3, dark colour
- Hot water
- Gas instantaneous with a performance of 5 stars
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
Built by Royal Constructions.
BASIX certificate
- Energy score
- 54 (target 50)
- Water score
- 52 (target 40)
- Thermal performance
- Pass
- Heating load
- 55 MJ/m² a year
- Cooling load
- 55 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 338 m²
- Unconditioned floor area
- 5 m²
- Site area
- 639 m²
- Roof area
- 190 m²
- Garden area
- 302 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 5 stars
- Solar panels
- 2 kW
- Rainwater tank
- 4,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Certificate 1258451S, issued 11 November 2021, from the council's DA documents.
NatHERS certificate
- Star rating
- 5.1 stars
- Rated with
- BERS Pro v4.4.0.6 (3.21)
- Rated on
- 11 Nov 2021
- Wall insulation
- R2.5
- Ceiling insulation
- R2.5, R4
- Floor insulation
- R2.5
- LED downlights
- 89
- Living room glazing by direction
- N 22.4 m², E 1.8 m², W 20.4 m²
- All glazing by direction
- N 34.4 m², E 6.4 m², S 26.2 m², W 25 m²
Roof
- Corrugated Iron Bulk, Reflective Side Down, No Air Gap Above R1.3, dark colour
Window types
- ALM-002-01 A Aluminium B SG Clear: U-value 6.7, SHGC 0.7
- TIM-001-01 W Timber A SG Clear: U-value 5.4, SHGC 0.56
- AWS-001-01 A 502/504 Al Sliding Window SG 3Clr: U-value 6.4, SHGC 0.73
- AWS-007-01 A 516 Al Awining Window SG 3Clr: U-value 6.5, SHGC 0.66
- AWS-066-07 A RES SERIES 516 FIXED WINDOW SG 5mmClr: U-value 5.9, SHGC 0.75
- AWS-066-02 A RES SERIES 516 FIXED WINDOW SG 638ComPlyNtl: U-value 3.9, SHGC 0.47
- AWS-011-06 A 541/542 Al Sliding Door SG 6.38CP: U-value 4.4, SHGC 0.45
- AWS-011-01 A 541/542 Al Sliding Door SG 5Clr: U-value 6.2, SHGC 0.72
Window schedule
- LDRY-GF, window ALM-002-01 A: 600 × 610 mm facing E
- Media-GF, window AWS-001-01 A: 600 × 2,410 mm facing E
- Guest Room-GF, window AWS-007-01 A: 2,140 × 500 mm facing S
- Guest Room-GF, window AWS-007-01 A: 2,140 × 1,650 mm facing S
- Entry-GF, window TIM-001-01 W: 2,400 × 1,640 mm facing S
- B.Pantry-GF, window AWS-066-07 A: 600 × 1,570 mm facing E
- Ktch/Fam/Meals, window AWS-007-01 A: 2,140 × 1,210 mm facing W
- Ktch/Fam/Meals, window AWS-007-01 A: 2,140 × 1,210 mm facing W
- Ktch/Fam/Meals, window AWS-007-01 A: 2,140 × 1,210 mm facing W
- Ktch/Fam/Meals, window AWS-007-01 A: 2,830 × 1,210 mm facing W
- Ktch/Fam/Meals, window AWS-007-01 A: 2,830 × 1,210 mm facing W
- Ktch/Fam/Meals, window AWS-066-02 A: 2,830 × 4,090 mm facing N
- Ktch/Fam/Meals, window AWS-066-02 A: 2,800 × 2,050 mm facing W
- Ktch/Fam/Meals, window AWS-011-06 A: 3,080 × 3,500 mm facing N
- Ktch/Fam/Meals, window AWS-066-07 A: 600 × 3,000 mm facing E
- M.Bed-FF, window AWS-001-01 A: 600 × 3,000 mm facing W
- M.Bed-FF, window AWS-011-01 A: 2,400 × 3,500 mm facing N
- Retreat/M.Bed-F, window AWS-066-07 A: 1,200 × 3,000 mm facing N
- Bed 2-FF, window AWS-001-01 A: 600 × 2,170 mm facing E
- ENS/Bed 2/3-FF, window ALM-002-01 A: 600 × 850 mm facing E
- Bed 3-FF, window AWS-011-01 A: 2,400 × 3,000 mm facing S
- WIR/Bed 3-FF, window AWS-007-01 A: 2,140 × 610 mm facing S
- ENS/M.Bed-FF, window ALM-002-01 A: 600 × 1,690 mm facing W
- Bed 4-FF, window AWS-007-01 A: 2,140 × 500 mm facing S
- Bed 4-FF, window AWS-007-01 A: 2,140 × 1,650 mm facing S
- Bed 4-FF, window AWS-001-01 A: 600 × 2,170 mm facing W
- ENS/Bed 4-FF, window ALM-002-01 A: 600 × 850 mm facing W
- Void abv Entry, window AWS-066-07 A: 2,700 × 1,700 mm facing S
Certificate 0006778906, issued 11 November 2021, from the council's DA documents. Verify this certificate