Skip to main content

19 Patterson Avenue Kellyville NSW 2155

BASIX certificate and NatHERS rating

Finding the block on the map…

This home's BASIX certificate commits it to 1 kW of solar panels and a 3,150 litre rainwater tank. It beat its BASIX energy and water targets, scoring 72 against 70 for energy and 43 against 40 for water.

Key features

Windows
Up to aluminium frames 52.5 m², single glazing 52.5 m²
Wall insulation
All external walls fibreglass batts or roll
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket; Ceiling: none; roof: none
Hot water
Gas instantaneous with a performance of 4 stars
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

BASIX certificate

Energy score
72 (target 70)
Water score
43 (target 40)
Thermal performance
Pass
Materials score
-73
Heating load
38 MJ/m² a year
Cooling load
22 MJ/m² a year
Bedrooms
6
Conditioned floor area
310.9 m²
Unconditioned floor area
14.2 m²
Site area
698 m²
Roof area
308 m²
Garden area
281 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 4 stars
Solar panels
1 kW
Rainwater tank
3,150 litres
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 52.5 m², single glazing 52.5 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (polystyrene)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (not specified)
  • Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (polystyrene)
  • External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: none; roof: none.)

Certificate 1824672S_07, issued 22 April 2026, from the council's DA documents.

Other certificates for this address

BASIX certificate, certificate 1824672S_06, issued 7 April 2026

BASIX certificate

Energy score
72 (target 70)
Water score
43 (target 40)
Thermal performance
Pass
Materials score
-73
Heating load
38 MJ/m² a year
Cooling load
21 MJ/m² a year
Bedrooms
6
Conditioned floor area
310.9 m²
Unconditioned floor area
14.2 m²
Site area
698 m²
Roof area
308 m²
Garden area
281 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 4 stars
Solar panels
1 kW
Rainwater tank
3,150 litres
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 51.2 m², single glazing 51.2 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (polystyrene)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (not specified)
  • Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (polystyrene)
  • External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: none; roof: none.)

Certificate 1824672S_06, issued 7 April 2026, from the council's DA documents.

BASIX certificate, certificate 1824672S_05, issued 31 March 2026

BASIX certificate

Energy score
72 (target 70)
Water score
43 (target 40)
Thermal performance
Pass
Materials score
-73
Heating load
36 MJ/m² a year
Cooling load
24 MJ/m² a year
Bedrooms
6
Conditioned floor area
310.9 m²
Unconditioned floor area
14.2 m²
Site area
698 m²
Roof area
308 m²
Garden area
281 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 4 stars
Solar panels
1 kW
Rainwater tank
3,150 litres
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 56.1 m², single glazing 56.1 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (polystyrene)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (not specified)
  • Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (polystyrene)
  • External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: none; roof: none.)

Certificate 1824672S_05, issued 31 March 2026, from the council's DA documents.

BASIX certificate, certificate 1824672S_04, issued 19 March 2026

BASIX certificate

Energy score
72 (target 70)
Water score
43 (target 40)
Thermal performance
Pass
Materials score
-73
Heating load
34 MJ/m² a year
Cooling load
26 MJ/m² a year
Bedrooms
6
Conditioned floor area
310.9 m²
Unconditioned floor area
14.2 m²
Site area
698 m²
Roof area
308 m²
Garden area
281 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 4 stars
Solar panels
1 kW
Rainwater tank
3,150 litres
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 56.1 m², single glazing 56.1 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (polystyrene)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (not specified)
  • Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (polystyrene)
  • External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: none; roof: none.)

Certificate 1824672S_04, issued 19 March 2026, from the council's DA documents.

BASIX certificate, certificate 1824672S_03, issued 17 March 2026

BASIX certificate

Energy score
70 (target 70)
Water score
43 (target 40)
Thermal performance
Pass
Materials score
-73
Heating load
34 MJ/m² a year
Cooling load
26 MJ/m² a year
Bedrooms
6
Conditioned floor area
310.9 m²
Unconditioned floor area
14.2 m²
Site area
698 m²
Roof area
308 m²
Garden area
281 m²
Climate zone
NatHERS climate zone 28
Hot water
Electric heat pump with a performance of 31 to 35 STCs or better
Rainwater tank
3,150 litres
Fixtures
Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Clothes line
Yes
Maximum glazing
aluminium frames 56.1 m², single glazing 56.1 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (polystyrene)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (not specified)
  • Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (polystyrene)
  • External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: none; roof: none.)

Certificate 1824672S_03, issued 17 March 2026, from the council's DA documents.

BASIX certificate, certificate 1824672S_02, issued 3 December 2025

BASIX certificate

Energy score
70 (target 70)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-76
Heating load
30 MJ/m² a year
Cooling load
30 MJ/m² a year
Bedrooms
6
Conditioned floor area
330.4 m²
Unconditioned floor area
16.1 m²
Site area
698 m²
Roof area
302 m²
Garden area
259 m²
Climate zone
NatHERS climate zone 28
Hot water
Electric heat pump with a performance of 15 to 20 STCs or better
Rainwater tank
3,150 litres
Fixtures
Showerheads 4 star, toilets 3 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Clothes line
Yes
Maximum glazing
aluminium frames 60.6 m², single glazing 27 m², double glazing 33.6 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (polystyrene)
  • Floor: suspended floor above open subfloor, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (not specified)
  • Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (polystyrene)
  • External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: none; roof: none.)