Skip to main content

18 Cedar Cutters Way Bella Vista NSW 2153

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to 1 kW of solar panels and a 9,100 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 75 against 72 for energy and 62 against 40 for water.

Key features

Windows
40 windows and glazed doors: Aluminium Hinged Door DG 4Clr/10Ar/4Clr; Aluminium Bifold Door DG 4PbAS2/12Ar/4PbG; Aluminium Awning Window DG 4Clr/8/4Clr and 4 more types
Wall insulation
R2.5
Roof and ceiling insulation
Ceiling R2.5, R4, roof Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, light colour
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by Elandra Homes.

BASIX certificate

Energy score
75 (target 72)
Water score
62 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
11 MJ/m² a year
Cooling load
17 MJ/m² a year
Bedrooms
5
Conditioned floor area
460 m²
Unconditioned floor area
15.5 m²
Site area
700 m²
Roof area
365 m²
Garden area
284 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
1 kW
Rainwater tank
9,100 litres
Fixtures
Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 125.9 m², double glazing 125.9 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (not specified)
  • Floor: above habitable rooms or mezzanine, fibre cement; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: suspended floor above garage, fibre cement; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1796576S_02, issued 17 June 2025, from the council's DA documents.

NatHERS certificate

Star rating
7.1 stars
Rated with
BERS Pro v5.2.4 (3.23)
Rated on
22 May 2025
Wall insulation
R2.5
Ceiling insulation
R2.5, R4
Floor insulation
R2.5
Living room glazing by direction
N 21.3 m², E 16 m², W 22 m²
All glazing by direction
N 33.2 m², E 34.8 m², S 18 m², W 46.2 m²

Roof

  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, light colour
  • Waterproofing Membrane No Insulation, Only an Air Gap, medium colour

Window types

  • STG-028-300 Aluminium Hinged Door DG 4Clr/10Ar/4Clr: U-value 4.1, SHGC 0.53
  • STG-082-300 Aluminium Bifold Door DG 4PbAS2/12Ar/4PbG: U-value 3, SHGC 0.38
  • STG-001-019 Aluminium Awning Window DG 4Clr/8/4Clr: U-value 4.3, SHGC 0.57
  • STG-001-300 Aluminium Awning Window DG 4PbAS2/12Ar/4PbG: U-value 3, SHGC 0.41
  • STG-004-300 Aluminium Sliding Door DG 4PbAS2-10Ar-4PbG: U-value 2.7, SHGC 0.44
  • STG-078-300 Aluminium Fixed Window DG 4PbAS2/12Ar/4PbG: U-value 1.9, SHGC 0.48
  • STG-088-300 Aluminium Hinged Door DG 4PbAS2/12Ar/4PbG: U-value 3.3, SHGC 0.4

Window schedule

  • LAUNDRY, window STG-028-300: 2,400 × 900 mm facing W
  • PANTRY, window STG-082-300: 1,480 × 2,170 mm facing W
  • GUEST ENS, window STG-001-019: 900 × 1,210 mm facing S
  • GUEST, window STG-001-300: 1,500 × 2,170 mm facing S
  • GYM, window STG-004-300: 2,400 × 2,410 mm facing S
  • FOYER HALL, window STG-001-300: 1,500 × 2,650 mm facing N
  • FOYER HALL, window STG-078-300: 2,400 × 365 mm facing E
  • FOYER HALL, window STG-078-300: 2,400 × 365 mm facing E
  • FOYER HALL, window STG-078-300: 600 × 1,930 mm facing E
  • KIT FAM DIN, window STG-078-300: 2,400 × 3,990 mm facing W
  • KIT FAM DIN, window STG-078-300: 700 × 2,520 mm facing W
  • KIT FAM DIN, window STG-004-300: 2,400 × 4,430 mm facing W
  • KIT FAM DIN, window STG-001-300: 2,400 × 960 mm facing N
  • KIT FAM DIN, window STG-001-300: 2,400 × 960 mm facing N
  • THEATRE, window STG-001-300: 600 × 2,410 mm facing N
  • STUDY, window STG-001-300: 1,500 × 1,930 mm facing N
  • STUDY, window STG-078-300: 1,500 × 2,930 mm facing E
  • ENS 2, window STG-001-019: 600 × 610 mm facing S
  • BED 2, window STG-001-300: 1,500 × 610 mm facing S
  • BED 2, window STG-001-300: 1,500 × 610 mm facing S
  • BED 2, window STG-001-300: 1,500 × 4,920 mm facing W
  • ENS 1, window STG-001-019: 900 × 1,210 mm facing W
  • WIR 1, window STG-001-300: 900 × 850 mm facing W
  • BED 1, window STG-001-300: 2,400 × 3,990 mm facing W
  • BED 1, window STG-001-300: 900 × 4,000 mm facing N
  • FAM DIN VOID, window STG-078-300: 450 × 4,000 mm facing N
  • FAM DIN VOID, window STG-078-300: 450 × 4,000 mm facing N
  • FAM DIN VOID, window STG-078-300: 450 × 3,000 mm facing N
  • FAM DIN VOID, window STG-078-300: 450 × 3,000 mm facing N
  • LIV BAR UF HALL, window STG-001-300: 900 × 610 mm facing N
  • LIV BAR UF HALL, window STG-001-300: 900 × 610 mm facing N
  • LIV BAR UF HALL, window STG-088-300: 2,400 × 850 mm facing E
  • LOUNGE VOID, window STG-078-300: 2,400 × 3,870 mm facing N
  • LOUNGE VOID, window STG-078-300: 2,400 × 3,870 mm facing E
  • LOUNGE VOID, window STG-078-300: 2,400 × 1,930 mm facing E
  • BED 4, window STG-004-300: 2,400 × 2,410 mm facing E
  • BED 3, window STG-004-300: 2,400 × 2,410 mm facing E
  • BED 3, window STG-001-300: 1,200 × 3,370 mm facing S
  • ENS 3, window STG-001-019: 600 × 610 mm facing S
  • UF BATH, window STG-001-019: 600 × 2,050 mm facing S

Certificate 0011937026, issued 22 May 2025, from the council's DA documents. Verify this certificate

Other certificates for this address

BASIX certificate, certificate 1796576S, issued 22 May 2025

BASIX certificate

Energy score
75 (target 72)
Water score
53 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
11 MJ/m² a year
Cooling load
17 MJ/m² a year
Bedrooms
5
Conditioned floor area
460 m²
Unconditioned floor area
15.5 m²
Site area
700 m²
Roof area
365 m²
Garden area
284 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
1 kW
Rainwater tank
9,100 litres
Fixtures
Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 125.9 m², double glazing 125.9 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (not specified)
  • Floor: above habitable rooms or mezzanine, fibre cement; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: suspended floor above garage, fibre cement; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1796576S, issued 22 May 2025, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.