16 Folsom Crescent North Kellyville NSW 2155
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to 3.3 kW of solar panels. It beat its BASIX energy and water targets, scoring 86 against 70 for energy and 45 against 40 for water.
Key features
- Windows
- Up to aluminium frames 128.8 m², single glazing 43.4 m², double glazing 85.4 m²
- Wall insulation
- Fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Clarendon Homes.
BASIX certificate
- Energy score
- 86 (target 70)
- Water score
- 45 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 31 MJ/m² a year
- Cooling load
- 29 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 489.7 m²
- Unconditioned floor area
- 20.5 m²
- Site area
- 966 m²
- Roof area
- 382 m²
- Garden area
- 517 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 3.3 kW
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 128.8 m², single glazing 43.4 m², double glazing 85.4 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 3.5 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3.5 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (not specified)
- Floor: suspended floor above open subfloor, particle board; frame: light steel frame (not specified)
- Floor: above habitable rooms or mezzanine, particle board; frame: light steel frame (not specified)
- Floor: suspended floor above garage, particle board; frame: light steel frame (not specified)
- Garage floor: concrete slab on ground, waffle pod slab (not specified)
- External wall: brick veneer; frame: light steel frame (fibreglass batts or roll+ foil/sarking)
- External wall: framed (fibre cement sheet or boards); frame: light steel frame (fibreglass batts or roll+ foil/sarking)
- External garage wall: brick veneer; frame: light steel frame (no added insulation)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: light steel frame (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1789251S, issued 27 March 2025, from the council's DA documents.