North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
15 Pilaster Street Gables NSW 2765
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to 2 kW of solar panels. It beat its BASIX energy and water targets, scoring 75 against 70 for energy and 46 against 40 for water.
Key features
- Windows
- Up to aluminium frames 95.7 m², single glazing 3.4 m², double glazing 92.3 m²
- Wall insulation
- All external walls fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump with a performance of 31 to 35 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Vpj Constructions & Services.
BASIX certificate
- Energy score
- 75 (target 70)
- Water score
- 46 (target 40)
- Thermal performance
- Pass
- Materials score
- -49
- Heating load
- 30 MJ/m² a year
- Cooling load
- 29 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 354.9 m²
- Unconditioned floor area
- 11 m²
- Site area
- 450 m²
- Roof area
- 219 m²
- Garden area
- 150 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Electric heat pump with a performance of 31 to 35 STCs or better
- Solar panels
- 2 kW
- Fixtures
- Showerheads 4 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 95.7 m², single glazing 3.4 m², double glazing 92.3 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 5 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 5 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 5 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 5 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - untreated softwood (no added insulation)
- Floor: suspended floor above garage, treated softwood; frame: timber - untreated softwood (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - untreated softwood. all external walls fibreglass batts or roll+ foil/sarking
- External garage wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1776431S_02, issued 20 December 2024, from the council's DA documents.