11 Dahlia Circuit North Kellyville NSW 2155
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 3 kW of solar panels and a 3,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 87 against 70.
Key features
- Windows
- 29 windows and glazed doors
- Wall insulation
- R2.7
- Roof and ceiling insulation
- Ceiling R5, R7
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 87 (target 70)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -53
- Heating load
- 33 MJ/m² a year
- Cooling load
- 27 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 297.3 m²
- Unconditioned floor area
- 7.7 m²
- Site area
- 600 m²
- Roof area
- 246 m²
- Garden area
- 350 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Solar panels
- 3 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 78.2 m², double glazing 78.2 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: above habitable rooms or mezzanine, treated softwood; frame: light steel frame (fibreglass batts or roll)
- Floor: suspended floor above garage, treated softwood; frame: light steel frame (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: light steel frame. all external walls fibreglass batts or roll
- Internal wall: plasterboard; frame: light steel frame (fibreglass batts or roll)
- Internal wall: plasterboard; frame: light steel frame (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1753483S, issued 28 June 2024, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- BERS Pro v5.1.9 (3.23)
- Rated on
- 28 Jun 2024
- Wall insulation
- R2.7
- Ceiling insulation
- R5, R7
- Floor insulation
- R2.7, R5
- Living room glazing by direction
- N 10.3 m², E 0.7 m², S 10.6 m², W 15.3 m²
- All glazing by direction
- N 21.6 m², E 9.2 m², S 18.1 m², W 29.4 m²
Window schedule
- Media/Games STG-006-23 A W6: 2,000 × 2,400 mm facing S
- Kitchen/Living/ STG-006-23 A W5: 2,000 × 2,400 mm facing S
- Kitchen/Living/ STG-004-15 A W3: 2,400 × 3,200 mm facing W
- Kitchen/Living/ STG-004-15 A W4: 2,400 × 2,400 mm facing S
- Kitchen/Living/ STG-006-23 A W7: 2,000 × 2,600 mm facing W
- Laundry STG-004-15 A W29: 2,100 × 2,100 mm facing E
- Lounge STG-001-32 A W9: 2,000 × 600 mm facing W
- Lounge STG-001-32 A W8: 2,000 × 600 mm facing W
- Study STG-078-04 A W1: 2,000 × 1,100 mm facing W
- Study STG-001-32 A W11: 2,000 × 2,100 mm facing N
- Study STG-078-04 A W10: 2,000 × 1,000 mm facing N
- CL STG-001-32 A W12: 2,000 × 700 mm facing N
- Rumpus/Sitting STG-004-15 A W2: 2,400 × 3,600 mm facing N
- Rumpus/Sitting STG-001-32 A W15: 1,200 × 800 mm facing N
- Rumpus/Sitting STG-078-04 A W14: 600 × 1,200 mm facing N
- Rumpus/Sitting STG-078-04 A W13: 600 × 1,200 mm facing E
- Ensuite STG-006-23 A W27: 1,500 × 1,800 mm facing S
- Ensuite STG-078-04 A W28: 1,500 × 900 mm facing E
- Ensuite STG-006-23 A W26: 900 × 600 mm facing E
- Bedroom 1 STG-004-15 A W20: 2,400 × 2,100 mm facing W
- WIR STG-001-32 A W21: 1,800 × 600 mm facing W
- Bedroom 2/WIR STG-006-23 A W19: 1,200 × 2,100 mm facing W
- Ensuite2 STG-001-32 A W24: 1,200 × 800 mm facing W
- Ensuite3 STG-001-32 A W25: 1,200 × 800 mm facing E
- Bedroom 3/WIR STG-006-23 A W22: 700 × 1,800 mm facing E
- Ensuite4 STG-001-32 A W23: 1,200 × 800 mm facing W
- Bedroom 4/WIR STG-078-04 A W18: 1,200 × 1,100 mm facing W
- Bedroom 4/WIR STG-001-32 A W16: 1,200 × 2,100 mm facing N
- Bedroom 4/WIR STG-078-04 A W17: 1,200 × 1,000 mm facing N
Certificate 0009577065-01, issued 28 June 2024, from the council's DA documents. Verify this certificate