North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
11 Arris Road Gables NSW 2765
BASIX certificate and NatHERS rating
Finding the block on the map…
This home has a NatHERS rating of 7.4 stars out of 10. It beat its BASIX water target, scoring 44 against 40.
Key features
- Windows
- Up to aluminium frames 50.9 m², single glazing 3.4 m², double glazing 47.6 m²
- Wall insulation
- Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 44 (target 40)
- Thermal performance
- Pass
- Materials score
- -87
- Heating load
- 37 MJ/m² a year
- Cooling load
- 16 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 266.5 m²
- Unconditioned floor area
- 18.4 m²
- Site area
- 466 m²
- Roof area
- 257 m²
- Garden area
- 195 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Electric heat pump
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 50.9 m², single glazing 3.4 m², double glazing 47.6 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: suspended floor above open subfloor, particle board; frame: light steel frame (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, particle board; frame: light steel frame (fibreglass batts or roll)
- Floor: suspended floor above garage, particle board; frame: light steel frame (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: light steel frame (fibreglass batts or roll)
- External wall: framed (solid or reconstituted timber weatherboard); frame: light steel frame (fibreglass batts or roll)
- External garage wall: brick veneer; frame: light steel frame (no added insulation)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: light steel frame (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, light steel frame (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1828924S_03, issued 2 April 2026, from the council's DA documents.
NatHERS certificate
- Star rating
- 7.4 stars
- Rated with
- FirstRate5: 5.5.5a (3.22)
- Rated on
- 2 Apr 2026
Certificate MGNNUACA4P-01, issued 2 April 2026, from the council's DA documents. Verify this certificate
Other certificates for this address
BASIX certificate, certificate 1828924S_02, issued 27 February 2026
BASIX certificate
- Energy score
- 70 (target 70)
- Water score
- 49 (target 40)
- Thermal performance
- Pass
- Materials score
- -87
- Heating load
- 37 MJ/m² a year
- Cooling load
- 16 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 266.5 m²
- Unconditioned floor area
- 18.4 m²
- Site area
- 466 m²
- Roof area
- 257 m²
- Garden area
- 195 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Electric heat pump
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 50.9 m², single glazing 3.4 m², double glazing 47.6 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: suspended floor above open subfloor, particle board; frame: light steel frame (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, particle board; frame: light steel frame (fibreglass batts or roll)
- Floor: suspended floor above garage, particle board; frame: light steel frame (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: light steel frame (fibreglass batts or roll)
- External wall: framed (solid or reconstituted timber weatherboard); frame: light steel frame (fibreglass batts or roll)
- External garage wall: brick veneer; frame: light steel frame (no added insulation)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: light steel frame (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, light steel frame (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1828924S_02, issued 27 February 2026, from the council's DA documents.