North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
47 Mintaro Avenue Strathfield NSW 2135
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to a 1,500 litre rainwater tank. It beat its BASIX water target, scoring 42 against 40.
Key features
- Windows
- Up to aluminium frames 210.4 m², single glazing 9.3 m², double glazing 201.1 m²
- Wall insulation
- Polystyrene; No added insulation
- Roof and ceiling insulation
- Ceiling: rockwool batts, roll or pump-in; roof: none
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 72 (target 72)
- Water score
- 42 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 20 MJ/m² a year
- Cooling load
- 10 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 474.1 m²
- Unconditioned floor area
- 184.4 m²
- Site area
- 774 m²
- Roof area
- 250 m²
- Garden area
- 341 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 6 stars
- Rainwater tank
- 1,500 litres
- Fixtures
- Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 210.4 m², single glazing 9.3 m², double glazing 201.1 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 6 Star (old label)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 6 Star (old label)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 6 Star (old label)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 6 Star (old label)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (polystyrene)
- Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: no frame (polystyrene)
- Garage floor: concrete slab on ground (polystyrene)
- External wall: cavity brick; frame: no frame (polystyrene)
- External wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- External garage wall: concrete block/plasterboard; frame: timber - untreated softwood (polystyrene)
- Internal wall: single skin masonry; frame: no frame (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, no frame (ceiling: rockwool batts, roll or pump-in; roof: none.)
Certificate 1788138S, issued 20 March 2025, from the council's DA documents.
Is this your home? Ask us to remove these details.