North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
33 High Street Strathfield NSW 2135
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to a 2,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX water target, scoring 41 against 40.
Key features
- Windows
- 30 windows and glazed doors: Aluminium A SG Clear; Aluminium B SG Clear; IDEAL 2000 Fixed Window DG LightBridgeNext 688Lam-12-6mm and 3 more types
- Wall insulation
- R2.0, R1.5
- Roof and ceiling insulation
- Ceiling R2.0, R4.0, R6.0, roof Slab:Slab - Suspended Slab : 200mm: 200mm Suspended Slab 0.0, medium colour
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 72 (target 72)
- Water score
- 41 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 23 MJ/m² a year
- Cooling load
- 7 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 498.6 m²
- Unconditioned floor area
- 169 m²
- Site area
- 774 m²
- Roof area
- 220 m²
- Garden area
- 341 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 6 stars
- Rainwater tank
- 2,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 186.9 m², single glazing 39 m², double glazing 147.9 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 6 Star (old label)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 6 Star (old label)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 6 Star (old label)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 6 Star (old label)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (not specified)
- Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: no frame (not specified)
- Garage floor: concrete slab on ground (not specified)
- External wall: cavity brick; frame: no frame. all external walls not specified
- External garage wall: concrete block/plasterboard; frame: no frame (not specified)
- Internal wall: single skin masonry; frame: no frame (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1800884S, issued 22 June 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 7.1 stars
- Rated with
- FirstRate5: 5.5.5a (3.22)
- Rated on
- 21 Jun 2025
- Wall insulation
- R2.0, R1.5
- Ceiling insulation
- R2.0, R4.0, R6.0
- Floor insulation
- R2.0, R1.5
- Living room glazing by direction
- NE 29.2 m², NW 6.3 m²
- All glazing by direction
- NE 51.9 m², SE 22.1 m², SW 53.4 m², NW 59.5 m²
Roof
- Slab:Slab - Suspended Slab : 200mm: 200mm Suspended Slab 0.0, medium colour
Window types
- ALM-001-01 A Aluminium A SG Clear: U-value 6.7, SHGC 0.57
- ALM-002-01 A Aluminium B SG Clear: U-value 6.7, SHGC 0.7
- ALU-012-01 A IDEAL 2000 Fixed Window DG LightBridgeNext 688Lam-12-6mm: U-value 1.46, SHGC 0.45
- ALU-002-01 A Awning Id4000 DG 638ComPlsClr-12Ar-6mmClr: U-value 1.67, SHGC 0.31
- ALU-005-01 A Sliding Door DG 638ComPlsClr-10Ar-6mmClr: U-value 1.85, SHGC 0.44
- ALU-001-01 A Casement Id4000 DG 638ComPlsClr-12Ar-6mmClr: U-value 1.66, SHGC 0.31
Window schedule
- Bedroom Guest, window ALU-012-01 A: 3,100 × 3,540 mm facing SW
- Bedroom Guest, window ALU-002-01 A: 3,100 × 700 mm facing SE
- ENS Guest, window ALM-001-01 A: 1,500 × 900 mm facing SE
- Library, window ALU-012-01 A: 3,100 × 3,540 mm facing SW
- Library, window ALU-002-01 A: 3,100 × 1,300 mm facing NW
- WC, window ALM-001-01 A: 1,500 × 900 mm facing SE
- Bath, window ALM-002-01 A: 3,100 × 1,100 mm facing SE
- Kitchen/Living, window ALM-002-01 A: 3,400 × 1,840 mm facing NW
- Kitchen/Living, window ALU-005-01 A: 3,400 × 8,580 mm facing NE
- LDRY, window ALM-001-01 A: 3,400 × 1,000 mm facing NE
- Butlers, window ALM-002-01 A: 2,100 × 1,200 mm facing SE
- Store, window ALM-002-01 A: 3,100 × 1,100 mm facing SE
- Entry, window ALU-001-01 A: 2,810 × 2,700 mm facing SW
- Formal Dning, window ALU-005-01 A: 3,300 × 6,680 mm facing NW
- WIR3, window ALU-001-01 A: 2,600 × 1,530 mm facing SW
- Bedroom 3, window ALU-001-01 A: 2,600 × 1,530 mm facing SW
- Bedroom 3, window ALU-001-01 A: 2,600 × 1,530 mm facing SW
- ENS3, window ALM-001-01 A: 1,100 × 1,600 mm facing NW
- ENS2, window ALM-001-01 A: 1,000 × 1,600 mm facing SE
- Bedroom 2, window ALU-001-01 A: 2,600 × 1,530 mm facing SW
- Bedroom 2, window ALU-001-01 A: 2,600 × 1,530 mm facing SW
- WIR2, window ALU-001-01 A: 2,600 × 1,530 mm facing SW
- ENS Master, window ALM-002-01 A: 2,600 × 2,960 mm facing NE
- WC Master, window ALM-001-01 A: 1,100 × 1,495 mm facing SE
- WIR Master, window ALM-002-01 A: 2,600 × 1,100 mm facing SE
- Bedroom 4, window ALU-012-01 A: 2,600 × 2,000 mm facing NW
- Bedroom Master, window ALU-002-01 A: 2,600 × 1,100 mm facing NW
- Bedroom Master, window ALU-012-01 A: 2,600 × 4,490 mm facing NE
- Bath L1, window ALM-001-01 A: 1,100 × 1,600 mm facing SE
- Landing, window ALU-012-01 A: 2,600 × 6,680 mm facing NW
Certificate OTY93ZYFHL, issued 21 June 2025, from the council's DA documents. Verify this certificate
Is this your home? Ask us to remove these details.