24 Arthur Street Strathfield NSW 2135

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 1.8 kW of solar panels and a 3,500 litre rainwater tank. Its NatHERS certificate lists insulation in the ceiling and floor.

Key features

Windows
39 windows and glazed doors: Aluminium B SG Clear; Al Thermally Broken A DG Argon Fill High Solar Gain low-E -Clear; Al Thermally Broken B DG Argon Fill High Solar Gain low-E -Clear
Wall insulation
Polystyrene; Rockwool batts, roll or pump-in
Roof and ceiling insulation
Ceiling R2.0, R6.0, roof Slab:Slab - Suspended Slab : 200mm: 200mm Suspended Slab 0.0, medium colour
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
Airconditioning ducting only (living area and bedroom)

BASIX certificate

Energy score
72 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
16 MJ/m² a year
Cooling load
14 MJ/m² a year
Bedrooms
5
Conditioned floor area
370.4 m²
Unconditioned floor area
9.1 m²
Site area
696 m²
Roof area
270 m²
Garden area
294 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
1.8 kW
Rainwater tank
3,500 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 172.2 m², single glazing 3.6 m², double glazing 168.6 m²

Heating

  • Living area: airconditioning ducting only; Energy rating: n/a
  • Bedroom: airconditioning ducting only; Energy rating: n/a

Cooling

  • Living area: airconditioning ducting only; Energy rating: n/a
  • Bedroom: airconditioning ducting only; Energy rating: n/a

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (polystyrene)
  • Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (polystyrene)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: light steel frame (no added insulation)
  • Floor: suspended floor above garage, concrete - suspended; frame: no frame (polystyrene)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: cavity brick; frame: no frame (polystyrene)
  • External wall: brick veneer; frame: timber - untreated softwood (rockwool batts, roll or pump-in)
  • External garage wall: cavity brick; frame: no frame (polystyrene)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, light steel frame (ceiling: fibreglass batts or roll; roof: none.)

Certificate 1817065S, issued 14 October 2025, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
9 Oct 2025
Ceiling insulation
R2.0, R6.0
Floor insulation
R1.0, R2.0
Living room glazing by direction
NE 9.3 m², SE 29.4 m², SW 13.5 m², NW 16.2 m²
All glazing by direction
NE 30.9 m², SE 64.8 m², SW 38 m², NW 38.4 m²

Roof

  • Slab:Slab - Suspended Slab : 200mm: 200mm Suspended Slab 0.0, medium colour
  • Cont:Attic-Continuous 1.3, medium colour

Window types

  • ALM-002-01 A Aluminium B SG Clear: U-value 6.7, SHGC 0.7
  • ATB-005-03 B Al Thermally Broken A DG Argon Fill High Solar Gain low-E -Clear: U-value 2.91, SHGC 0.44
  • ATB-006-03 B Al Thermally Broken B DG Argon Fill High Solar Gain low-E -Clear: U-value 2.9, SHGC 0.51

Window schedule

  • Garage, window ALM-002-01 A: 1,200 × 3,000 mm facing SW
  • ENS G, window ATB-005-03 B: 1,200 × 800 mm facing SW
  • Bedroom G, window ATB-006-03 B: 3,000 × 4,200 mm facing SE
  • LDRY, window ATB-005-03 B: 2,700 × 900 mm facing NE
  • Kitchen/Living, window ATB-006-03 B: 3,000 × 4,200 mm facing NW
  • Kitchen/Living, window ATB-006-03 B: 3,000 × 4,200 mm facing SE
  • Kitchen/Living, window ATB-006-03 B: 3,000 × 4,500 mm facing SW
  • Kitchen/Living, window ATB-006-03 B: 3,000 × 5,600 mm facing SE
  • Kitchen/Living, window ATB-006-03 B: 700 × 3,000 mm facing NE
  • GROUND CORRIDOR, window ATB-006-03 B: 3,000 × 3,000 mm facing SW
  • FORMAL LOUNGE, window ATB-005-03 B: 2,100 × 1,200 mm facing NW
  • FORMAL LOUNGE, window ATB-006-03 B: 900 × 1,200 mm facing NW
  • VOID FR, window ATB-006-03 B: 2,400 × 3,000 mm facing NE
  • VOID FR, window ATB-006-03 B: 2,400 × 3,000 mm facing NE
  • VOID RR, window ATB-006-03 B: 2,400 × 4,200 mm facing NW
  • Bedroom 3, window ATB-005-03 B: 1,500 × 1,400 mm facing SE
  • Bedroom 3, window ATB-006-03 B: 900 × 1,400 mm facing SE
  • Bedroom 3, window ATB-005-03 B: 1,500 × 1,400 mm facing SE
  • Bedroom 3, window ATB-006-03 B: 900 × 1,400 mm facing SE
  • Bedroom 3, window ATB-005-03 B: 1,500 × 1,400 mm facing SE
  • Bedroom 3, window ATB-006-03 B: 900 × 1,400 mm facing SE
  • ENS 3, window ATB-006-03 B: 900 × 1,400 mm facing SW
  • ENS 2, window ATB-006-03 B: 900 × 1,200 mm facing SW
  • Bedroom 2, window ATB-006-03 B: 2,700 × 4,500 mm facing NW
  • ENS 4, window ATB-005-03 B: 900 × 1,000 mm facing NE
  • Bedroom 4, window ATB-005-03 B: 1,500 × 800 mm facing NE
  • Bedroom 4, window ATB-006-03 B: 900 × 800 mm facing NE
  • Bedroom 4, window ATB-005-03 B: 1,500 × 800 mm facing NE
  • Bedroom 4, window ATB-006-03 B: 900 × 800 mm facing NE
  • ENS M, window ATB-006-03 B: 900 × 1,600 mm facing SW
  • WIR M, window ATB-005-03 B: 1,500 × 1,300 mm facing SE
  • Bedroom M, window ATB-006-03 B: 2,400 × 4,500 mm facing SE
  • FAMILY, window ATB-005-03 B: 1,500 × 1,000 mm facing NE
  • FAMILY, window ATB-006-03 B: 900 × 1,000 mm facing NE
  • FAMILY, window ATB-005-03 B: 1,500 × 1,000 mm facing NE
  • FAMILY, window ATB-006-03 B: 900 × 1,000 mm facing NE
  • FAMILY, window ATB-005-03 B: 1,500 × 1,000 mm facing NE
  • FAMILY, window ATB-006-03 B: 900 × 1,000 mm facing NE
  • UPPER CORRIDOR, window ATB-006-03 B: 2,400 × 3,000 mm facing SW

Certificate 4CWW3UEPFO, issued 9 October 2025, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related