23 Amaroo Avenue Strathfield NSW 2135

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to 2.5 kW of solar panels and a 3,500 litre rainwater tank. Its NatHERS certificate lists insulation in the floor. It beat its BASIX energy target, scoring 87 against 72.

Key features

Windows
34 windows and glazed doors: Aluminium B SG Tint; Al Thermally Broken B DG Argon Fill Tint-Clear; Al Thermally Broken B DG Argon Fill High Solar Gain low-E - Clear and 1 more types
Wall insulation
All external walls none
Roof and ceiling insulation
Roof Added insulation absorptance Roof Colour FLAT-01: Flat Framed / Skillion Metal Roof & Flat PB Ceiling 1.30, medium colour
Hot water
Gas instantaneous with a performance of 5 stars
Air conditioning and heating
3-phase airconditioning (living area)

BASIX certificate

Energy score
87 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
14 MJ/m² a year
Cooling load
15 MJ/m² a year
Bedrooms
6
Conditioned floor area
299 m²
Unconditioned floor area
55.5 m²
Site area
585 m²
Roof area
227 m²
Garden area
218 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 5 stars
Solar panels
2.5 kW
Rainwater tank
3,500 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
aluminium frames 125 m², single glazing 125 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER < 2.5

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER < 2.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: cavity brick; frame: no frame. all external walls none
  • External garage wall: cavity brick; frame: no frame (no added insulation)
  • Internal wall shared with garage: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1825923S_02, issued 5 February 2026, from the council's DA documents.

NatHERS certificate

Star rating
7.1 stars
Rated with
Hero 4.1
Rated on
03 Feb 2026
Floor insulation
R1.75
Living room glazing by direction
N 3.4 m², NNE 9.4 m², NE 3.4 m², ESE 21.9 m², WNW 30.7 m², NNW 3.4 m²
All glazing by direction
N 3.4 m², NNE 18.3 m², NE 3.4 m², ESE 48.3 m², SSW 15.9 m², WNW 45.5 m², NNW 3.4 m²

Roof

  • Added insulation absorptance Roof Colour FLAT-01: Flat Framed / Skillion Metal Roof & Flat PB Ceiling 1.30, medium colour
  • SLAB-100-CEIL-01: Concrete Slab (100mm) with Suspended PB Ceiling 0.00, medium colour

Window types

  • ALM-002-02 A Aluminium B SG Tint: U-value 6.6, SHGC 0.49
  • ATB-006-02 B Al Thermally Broken B DG Argon Fill Tint-Clear: U-value 3.4, SHGC 0.4
  • ATB-006-03 B Al Thermally Broken B DG Argon Fill High Solar Gain low-E - Clear: U-value 2.9, SHGC 0.51
  • ATB-006-04 B Al Thermally Broken B DG Argon Fill Low Solar Gain low-E - Clear: U-value 3, SHGC 0.26

Window schedule

  • BATH, window ALM-002-02 A: 900 × 1,500 mm facing SSW
  • BED 1, window ATB-006-02 B: 2,600 × 3,500 mm facing WNW
  • BED 1, window ATB-006-02 B: 1,200 × 5,000 mm facing NNE
  • BED 1 ENS, window ALM-002-02 A: 900 × 1,800 mm facing WNW
  • BED 2, window ATB-006-02 B: 1,500 × 2,700 mm facing WNW
  • BED 2/3 ENS, window ALM-002-02 A: 900 × 750 mm facing SSW
  • BED 3, window ATB-006-02 B: 900 × 2,700 mm facing SSW
  • BED 4, window ATB-006-02 B: 1,200 × 2,400 mm facing NNE
  • BED 4, window ATB-006-04 B: 2,600 × 3,000 mm facing ESE
  • BED 4, window ATB-006-02 B: 900 × 2,100 mm facing SSW
  • BED 4, window ATB-006-04 B: 2,600 × 2,500 mm facing ESE
  • BED 4, window ATB-006-04 B: 2,600 × 1,000 mm facing ESE
  • CHANGE ROOM, window ALM-002-02 A: 1,200 × 600 mm facing SSW
  • FAMILY AREA, window ATB-006-03 B: 2,600 × 2,610 mm facing ESE
  • GARAGE, window ATB-006-02 B: 900 × 1,200 mm facing SSW
  • GUEST BEDROOM, window ATB-006-04 B: 2,700 × 2,500 mm facing ESE
  • GUEST BEDROOM, window ATB-006-04 B: 2,700 × 1,000 mm facing ESE
  • GUEST BEDROOM, window ATB-006-02 B: 1,200 × 2,100 mm facing SSW
  • GUEST ENS, window ALM-002-02 A: 900 × 645 mm facing SSW
  • KITCHEN/LIVING, window ATB-006-02 B: 1,200 × 2,400 mm facing NNE
  • KITCHEN/LIVING, window ATB-006-04 B: 2,700 × 3,000 mm facing ESE
  • KITCHEN/LIVING, window ATB-006-02 B: 2,600 × 3,500 mm facing WNW
  • KITCHEN/LIVING, window ATB-006-03 B: 2,700 × 5,300 mm facing WNW
  • KITCHEN/LIVING, window ATB-006-02 B: 2,600 × 610 mm facing NNE
  • KITCHEN/LIVING, window ATB-006-02 B: 2,600 × 610 mm facing NNE
  • KITCHEN/LIVING, window ATB-006-02 B: 2,600 × 2,700 mm facing ESE
  • KITCHEN/LIVING, window ATB-006-03 B: 2,700 × 2,700 mm facing WNW
  • LAUNDRY, window ATB-006-02 B: 600 × 2,400 mm facing SSW
  • LAUNDRY, window ATB-006-02 B: 2,400 × 750 mm facing SSW
  • PANTRY, window ATB-006-02 B: 600 × 2,400 mm facing SSW
  • KITCHEN/LIVING, window ATB-006-03 B: 2,700 × 1,250 mm facing NNW
  • KITCHEN/LIVING, window ATB-006-03 B: 2,700 × 1,250 mm facing N
  • KITCHEN/LIVING, window ATB-006-03 B: 2,700 × 1,250 mm facing NNE
  • KITCHEN/LIVING, window ATB-006-03 B: 2,700 × 1,250 mm facing NE

Certificate HR-XR77U4-06, issued 3 February 2026, from the council's DA documents. Verify this certificate