Skip to main content

192 Homebush Road Strathfield NSW 2135

Finding the block on the map…

BASIX certificate and NatHERS rating

This home's BASIX certificate commits it to 9 kW of solar panels and a 10,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 91 against 72 for energy and 50 against 40 for water.

Key features

Windows
Up to aluminium frames 162.7 m², double glazing 162.7 m²
Wall insulation
Fibreglass batts or roll; Foil-foam composite board+ foil/sarking
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket; Ceiling: fibreglass batts or roll; roof: none
Hot water
Gas instantaneous with a performance of 4 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by Jin & Son Building.

BASIX certificate

Energy score
91 (target 72)
Water score
50 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
21 MJ/m² a year
Cooling load
9 MJ/m² a year
Bedrooms
5
Conditioned floor area
406.7 m²
Unconditioned floor area
13.1 m²
Site area
702 m²
Roof area
310 m²
Garden area
302 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 4 stars
Solar panels
9 kW
Rainwater tank
10,000 litres
Fixtures
Showerheads 4 star, toilets 6 star, kitchen taps 6 star, basin taps 6 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 162.7 m², double glazing 162.7 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER < 2.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER < 2.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER < 2.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER < 2.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (polystyrene)
  • Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (fibreglass batts or roll)
  • Floor: suspended floor above garage, concrete - suspended; frame: no frame (fibreglass batts or roll)
  • Garage floor: concrete slab on ground (polystyrene)
  • External wall: concrete block/plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
  • External wall: cavity brick; frame: no frame (foil-foam composite board+ foil/sarking)
  • External garage wall: concrete block/plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, no frame (ceiling: fibreglass batts or roll; roof: none.)

Certificate 1788407S_02, issued 24 March 2025, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related