Skip to main content

16 Fraser Street Strathfield NSW 2135

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 3.5 kW of solar panels and a 4,500 litre rainwater tank. It beat its BASIX energy target, scoring 74 against 72.

Key features

Windows
36 windows and glazed doors: Al Sliding Window; Aluminium Fixed Light Window; Aluminium Sliding Window
Wall insulation
All external walls polystyrene+ foil/sarking
Roof and ceiling insulation
Roof Added insulation absorptance Roof Colour FLAT-01: Flat Framed / Skillion Metal Roof & Flat PB Ceiling 1.30, dark colour
Hot water
Gas storage with a performance of 4 stars
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

BASIX certificate

Energy score
74 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
17 MJ/m² a year
Cooling load
13 MJ/m² a year
Bedrooms
5
Conditioned floor area
566 m²
Unconditioned floor area
38 m²
Site area
1,162 m²
Roof area
371 m²
Garden area
407 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas storage with a performance of 4 stars
Solar panels
3.5 kW
Rainwater tank
4,500 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 165.5 m², single glazing 131.1 m², double glazing 34.4 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (polyurethane)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
  • Floor: suspended floor above garage, concrete - suspended; frame: no frame (polystyrene)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: cavity brick; frame: no frame. all external walls polystyrene+ foil/sarking
  • External garage wall: cavity brick; frame: no frame (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1779057S_03, issued 2 July 2025, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
Hero 4.1
Rated on
02 Jul 2025
Living room glazing by direction
ENE 27 m², WSW 7.4 m², NNW 10.4 m²
All glazing by direction
ENE 46.7 m², SSE 18.2 m², WSW 43.1 m², NNW 57.5 m²

Roof

  • Added insulation absorptance Roof Colour FLAT-01: Flat Framed / Skillion Metal Roof & Flat PB Ceiling 1.30, dark colour
  • (Woodland Grey) SLAB-100-CEIL-01: Concrete Slab (100mm) with Suspended PB Ceiling 0.00, medium colour

Window types

  • DOW-001-003 Al Sliding Window: U-value 4.5, SHGC 0.62
  • DOW-014-005 Aluminium Fixed Light Window: U-value 4.2, SHGC 0.6
  • DOW-018-006 Aluminium Sliding Window: U-value 3, SHGC 0.5

Window schedule

  • BED-2, window DOW-001-003: 2,050 × 1,200 mm facing ENE
  • BED-2, window DOW-001-003: 2,050 × 1,200 mm facing ENE
  • BED-3, window DOW-014-005: 2,250 × 2,520 mm facing WSW
  • BED-5, window DOW-001-003: 2,050 × 1,200 mm facing ENE
  • BED-5, window DOW-001-003: 2,050 × 1,200 mm facing ENE
  • BED-6, window DOW-001-003: 1,250 × 2,000 mm facing SSE
  • BED-M, window DOW-001-003: 2,550 × 1,385 mm facing WSW
  • BED-M, window DOW-001-003: 2,550 × 1,385 mm facing WSW
  • BED-M, window DOW-014-005: 2,550 × 1,385 mm facing WSW
  • ENS-2, window DOW-001-003: 1,100 × 1,200 mm facing NNW
  • ENS-3, window DOW-001-003: 1,100 × 1,200 mm facing NNW
  • ENS-5, window DOW-001-003: 1,100 × 1,200 mm facing SSE
  • ENS-6, window DOW-001-003: 1,100 × 1,200 mm facing SSE
  • ENS-M, window DOW-014-005: 1,500 × 2,600 mm facing WSW
  • ENS-O, window DOW-014-005: 1,937 × 1,385 mm facing WSW
  • ENTRY LOBBY, window DOW-014-005: 2,900 × 2,520 mm facing ENE
  • ENTRY LOBBY, window DOW-014-005: 2,345 × 4,294 mm facing NNW
  • ENTRY LOBBY, window DOW-014-005: 2,915 × 4,770 mm facing NNW
  • ENTRY LOBBY, window DOW-014-005: 2,700 × 850 mm facing NNW
  • ENTRY LOBBY, window DOW-014-005: 2,700 × 850 mm facing NNW
  • ENTRY LOBBY, window DOW-014-005: 2,700 × 850 mm facing NNW
  • ENTRY LOBBY, window DOW-001-003: 2,900 × 1,286 mm facing WSW
  • ENTRY LOBBY, window DOW-001-003: 2,900 × 1,314 mm facing WSW
  • HALL, window DOW-001-003: 2,350 × 1,090 mm facing ENE
  • HALL, window DOW-001-003: 2,050 × 2,600 mm facing NNW
  • HALL, window DOW-001-003: 2,050 × 2,600 mm facing NNW
  • HALL, window DOW-001-003: 2,050 × 1,415 mm facing NNW
  • KITCHEN/LIVING, window DOW-014-005: 2,615 × 3,988 mm facing NNW
  • KITCHEN/LIVING, window DOW-018-006: 3,015 × 8,960 mm facing ENE
  • KITCHEN/LIVING, window DOW-018-006: 2,915 × 2,520 mm facing WSW
  • LDRY, window DOW-001-003: 700 × 3,000 mm facing SSE
  • OFFICE, window DOW-014-005: 1,937 × 1,385 mm facing WSW
  • OFFICE, window DOW-014-005: 1,937 × 1,385 mm facing WSW
  • PANTRY, window DOW-014-005: 2,215 × 1,000 mm facing SSE
  • PANTRY, window DOW-014-005: 2,215 × 1,000 mm facing SSE
  • STAIR, window DOW-014-005: 2,750 × 2,380 mm facing SSE

Certificate HR-VZXPB4-03, issued 2 July 2025, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.