BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to 2.5 kW of solar panels and a 10,000 litre rainwater tank. It beat its BASIX energy target, scoring 74 against 72.
Key features
- Windows
- 36 windows and glazed doors: Al Thermally Broken A DG Air Fill High Solar Gain low-E - Clear; Al Thermally Broken B DG Air Fill High Solar Gain low-E - Clear
- Wall insulation
- All external walls foil-foam composite board
- Roof and ceiling insulation
- Roof Added insulation absorptance Roof Colour ATTIC-CONCTILE-01: Pitched / Attic Conc Tiled Roof (Roofspace) & Flat PB Ceiling 0.00, dark colour
- Hot water
- Gas instantaneous with a performance of 5 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 74 (target 72)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 23 MJ/m² a year
- Cooling load
- 6 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 607 m²
- Unconditioned floor area
- 26 m²
- Site area
- 1,419 m²
- Roof area
- 556 m²
- Garden area
- 662 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 5 stars
- Solar panels
- 2.5 kW
- Rainwater tank
- 10,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 3 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 134 m², double glazing 134 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (no added insulation)
- Floor: above habitable rooms or mezzanine, concrete - suspended; frame: light steel frame (no added insulation)
- Floor: suspended floor above garage, concrete - suspended; frame: no frame (no added insulation)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: cavity brick; frame: no frame. all external walls foil-foam composite board
- Internal wall: single skin masonry; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1809280S, issued 20 August 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 7.1 stars
- Rated with
- Hero 4.1
- Rated on
- 20 Aug 2025
- Living room glazing by direction
- N 24 m², S 26 m²
- All glazing by direction
- N 45.3 m², E 28 m², S 40.9 m², W 19.5 m²
Roof
- Added insulation absorptance Roof Colour ATTIC-CONCTILE-01: Pitched / Attic Conc Tiled Roof (Roofspace) & Flat PB Ceiling 0.00, dark colour
- (Terracota Tiles) FLAT-04: Flat Framed / Skillion Tile Roof & Cathedral PB Ceiling (11°-33°) 0.00, dark colour
- (Terracota Tiles) SLAB-100-CEIL-01: Concrete Slab (100mm) with Suspended PB Ceiling 0.00, medium colour
- SLAB-100-EXP-01: Concrete Slab (100mm) with Exposed Concrete Ceiling 0.00, medium colour
Window types
- ATB-003-03 B Al Thermally Broken A DG Air Fill High Solar Gain low-E - Clear: U-value 3.1, SHGC 0.39
- ATB-004-03 B Al Thermally Broken B DG Air Fill High Solar Gain low-E - Clear: U-value 3.1, SHGC 0.49
Window schedule
- B3 Ens, window ATB-003-03 B: 1,200 × 750 mm facing W
- B6 Ens, window ATB-003-03 B: 1,200 × 750 mm facing E
- Bed 3, window ATB-003-03 B: 2,600 × 1,600 mm facing N
- Bed 4, window ATB-003-03 B: 1,200 × 2,400 mm facing W
- Bed 5, window ATB-004-03 B: 2,400 × 1,600 mm facing S
- Bed 5, window ATB-004-03 B: 2,400 × 1,600 mm facing S
- Bed 6, window ATB-003-03 B: 2,600 × 1,600 mm facing N
- Entry Lobby, window ATB-004-03 B: 400 × 2,500 mm facing N
- Entry Lobby, window ATB-004-03 B: 2,100 × 300 mm facing N
- Entry Lobby, window ATB-004-03 B: 2,100 × 300 mm facing N
- Entry Lobby, window ATB-004-03 B: 1,200 × 2,500 mm facing N
- FF Hallway, window ATB-003-03 B: 2,400 × 1,800 mm facing W
- FF Hallway, window ATB-004-03 B: 2,400 × 5,700 mm facing E
- FF Laundry, window ATB-003-03 B: 1,200 × 1,600 mm facing W
- Formal Lounge/Dining, window ATB-003-03 B: 2,400 × 1,600 mm facing N
- Formal Lounge/Dining, window ATB-003-03 B: 2,400 × 1,600 mm facing N
- Formal Lounge/Dining, window ATB-003-03 B: 2,400 × 1,600 mm facing S
- Formal Lounge/Dining, window ATB-003-03 B: 2,400 × 1,600 mm facing S
- GF Laundry, window ATB-003-03 B: 1,200 × 600 mm facing W
- GF PWD, window ATB-003-03 B: 1,200 × 750 mm facing W
- Gallery/Breezeway, window ATB-004-03 B: 2,400 × 5,600 mm facing E
- Kitchen/Living (Grand Room), window ATB-004-03 B: 2,400 × 1,600 mm facing N
- Kitchen/Living (Grand Room), window ATB-004-03 B: 2,400 × 1,600 mm facing N
- Guens Ens, window ATB-003-03 B: 1,200 × 750 mm facing W
- Guest Bed, window ATB-003-03 B: 1,200 × 2,400 mm facing W
- Kitchen/Living (Grand Room), window ATB-003-03 B: 2,700 × 1,600 mm facing S
- Kitchen/Living (Grand Room), window ATB-003-03 B: 2,700 × 1,600 mm facing S
- Kitchen/Living (Grand Room), window ATB-003-03 B: 2,700 × 1,600 mm facing S
- Kitchen/Living (Grand Room), window ATB-004-03 B: 1,800 × 3,000 mm facing S
- Kitchen/Living (Grand Room), window ATB-003-03 B: 2,700 × 1,600 mm facing N
- Kitchen/Living (Grand Room), window ATB-003-03 B: 2,700 × 1,600 mm facing N
- Master Bed, window ATB-004-03 B: 2,400 × 3,000 mm facing S
- Master Ens, window ATB-003-03 B: 1,200 × 1,800 mm facing W
- Office/Library, window ATB-003-03 B: 2,400 × 1,600 mm facing N
- Office/Library, window ATB-003-03 B: 2,400 × 1,600 mm facing N
- Scullery, window ATB-003-03 B: 1,200 × 1,600 mm facing W
Certificate HR-FKE7CL-01, issued 20 August 2025, from the council's DA documents. Verify this certificate