BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 4 kW of solar panels and a 6,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 75 against 72.

Key features

Windows
46 windows and glazed doors: Aluminium A SG High Solar Gain Low-E; Aluminium B SG High Solar Gain Low-E; Aluminium A DG Air Fill High Solar Gain low-E - Clear and 5 more types
Wall insulation
R2
Roof and ceiling insulation
Ceiling R1, R5, roof Waterproofing Membrane No Added Insulation, No air Gap, light colour
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
75 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
19 MJ/m² a year
Cooling load
11 MJ/m² a year
Bedrooms
6
Conditioned floor area
488.7 m²
Unconditioned floor area
59.1 m²
Site area
1,114 m²
Roof area
500 m²
Garden area
505 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
4 kW
Rainwater tank
6,000 litres
Fixtures
Showerheads 4 star, toilets 6 star, kitchen taps 6 star, basin taps 6 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
aluminium frames 280.5 m², single glazing 7 m², double glazing 273.5 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground (no added insulation)
  • Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: no frame (no added insulation)
  • Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (polystyrene)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
  • Floor: suspended floor above garage, concrete - suspended; frame: no frame (fibreglass batts or roll)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: cavity brick; frame: timber - H2 treated softwood. all external walls rockwool batts, roll or pump-in
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, timber - H2 treated softwood (ceiling: rockwool batts, roll or pump-in; roof: none.)

Certificate 1378675S_02, issued 4 September 2024, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
BERS Pro v5.1.7 (3.22)
Rated on
05 Dec 2023
Wall insulation
R2
Ceiling insulation
R1, R5
Floor insulation
R2, R1
LED downlights
100
Living room glazing by direction
N 35.4 m², W 18.9 m²
All glazing by direction
N 99.8 m², E 44.3 m², S 86.9 m², W 49.6 m²

Roof

  • Waterproofing Membrane No Added Insulation, No air Gap, light colour

Window types

  • ALM-001-03 A Aluminium A SG High Solar Gain Low-E: U-value 5.4, SHGC 0.49
  • ALM-002-03 A Aluminium B SG High Solar Gain Low-E: U-value 5.4, SHGC 0.58
  • ALM-003-03 A Aluminium A DG Air Fill High Solar Gain low-E - Clear: U-value 4.3, SHGC 0.47
  • ALM-004-03 A Aluminium B DG Air Fill High Solar Gain low-E - Clear: U-value 4.3, SHGC 0.53
  • ATB-003-03 B Al Thermally Broken A DG Air Fill High Solar Gain low-E -Clear: U-value 3.1, SHGC 0.39
  • ATB-004-03 B Al Thermally Broken B DG Air Fill High Solar Gain low-E -Clear: U-value 3.1, SHGC 0.49
  • ATB-006-03 B Al Thermally Broken B DG Argon Fill High Solar Gain low-E - Clear: U-value 2.9, SHGC 0.51
  • VEL-010-02 W VELUX VS - Ventilating Skylight DG 3mm LoE 366 / 10.5mm Argon Gap / 3mm Clear: U-value 2.6, SHGC 0.21

Window schedule

  • ENTRY HALLWAY, window ATB-006-03 B: 3,000 × 4,250 mm facing S
  • LIBRARY, window ATB-006-03 B: 3,000 × 2,400 mm facing E
  • LIBRARY, window ATB-006-03 B: 3,000 × 1,200 mm facing E
  • LIBRARY, window ATB-006-03 B: 3,000 × 4,100 mm facing S
  • PWD 2, window ALM-001-03 A: 3,000 × 600 mm facing E
  • LDRY, window ALM-002-03 A: 3,000 × 600 mm facing E
  • LDRY, window ALM-001-03 A: 3,000 × 900 mm facing E
  • SCULLERY, window ATB-003-03 B: 3,000 × 2,500 mm facing E
  • KITCHEN DINING LIVIN, window ATB-004-03 B: 3,000 × 2,100 mm facing W
  • KITCHEN DINING LIVIN, window ATB-004-03 B: 3,000 × 4,400 mm facing N
  • KITCHEN DINING LIVIN, window ATB-004-03 B: 3,000 × 1,400 mm facing N
  • KITCHEN DINING LIVIN, window ATB-004-03 B: 3,000 × 4,200 mm facing W
  • KITCHEN DINING LIVIN, window ATB-004-03 B: 3,000 × 6,000 mm facing N
  • OFFICE, window ATB-006-03 B: 3,000 × 1,800 mm facing W
  • OFFICE, window ATB-006-03 B: 3,000 × 800 mm facing W
  • OFFICE, window ATB-006-03 B: 3,000 × 1,500 mm facing N
  • OFFICE, window ATB-006-03 B: 3,000 × 2,700 mm facing N
  • PWD 1, window ALM-001-03 A: 600 × 1,200 mm facing W
  • GUEST BED 1, window ATB-004-03 B: 3,000 × 3,500 mm facing S
  • NANNY BED 2, window ATB-004-03 B: 3,000 × 3,500 mm facing S
  • ENS GUEST, window ATB-004-03 B: 3,000 × 1,400 mm facing S
  • ENS NANNY, window ATB-003-03 B: 2,400 × 600 mm facing W
  • HALLWAY FF, window ALM-004-03 A: 2,800 × 2,200 mm facing N
  • HALLWAY FF, window ALM-004-03 A: 2,800 × 600 mm facing N
  • HALLWAY FF, window ALM-004-03 A: 2,800 × 3,000 mm facing W
  • HALLWAY FF, window ATB-006-03 B: 2,800 × 4,250 mm facing S
  • VOID, window ATB-004-03 B: 2,800 × 5,600 mm facing N
  • BEDROOM 5, window ALM-004-03 A: 2,800 × 2,600 mm facing S
  • BEDROOM 4, window ATB-004-03 B: 2,800 × 3,800 mm facing S
  • WIR MASTER, window ALM-004-03 A: 2,800 × 2,700 mm facing E
  • WIR MASTER, window ALM-004-03 A: 2,800 × 400 mm facing N
  • WIR MASTER, window ALM-004-03 A: 2,800 × 1,200 mm facing N
  • WIR MASTER, window ALM-003-03 A: 600 × 9,100 mm facing E
  • WIR MASTER, window ALM-003-03 A: 600 × 5,100 mm facing S
  • ENS MASTER BED, window ATB-004-03 B: 2,800 × 949 mm facing S
  • ENS MASTER BED, window ATB-004-03 B: 2,800 × 400 mm facing S
  • ENS MASTER BED, window ALM-004-03 A: 2,800 × 600 mm facing E
  • ENS MASTER BED, window ALM-004-03 A: 2,800 × 600 mm facing E
  • ENS MASTER BED, window ALM-004-03 A: 2,800 × 600 mm facing E
  • ENS MASTER BED, window ALM-004-03 A: 2,800 × 600 mm facing E
  • MASTER BED 3, window ALM-004-03 A: 2,800 × 3,200 mm facing W
  • MASTER BED 3, window ALM-004-03 A: 2,800 × 4,700 mm facing N
  • ENS 5, window ALM-004-03 A: 2,800 × 600 mm facing W
  • BEDROOM 6, window ALM-004-03 A: 2,800 × 800 mm facing N
  • BEDROOM 6, window ALM-004-03 A: 2,800 × 3,000 mm facing N
  • ENS 6, window ALM-004-03 A: 2,800 × 600 mm facing W

Certificate 0009110685, issued 5 December 2023, from the council's DA documents. Verify this certificate

Other certificates for this address

BASIX certificate, certificate 1378675S, issued 5 December 2023

BASIX certificate

Energy score
75 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
19 MJ/m² a year
Cooling load
11 MJ/m² a year
Bedrooms
6
Conditioned floor area
488.7 m²
Unconditioned floor area
59.1 m²
Site area
1,114 m²
Roof area
500 m²
Garden area
501 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
4 kW
Rainwater tank
6,000 litres
Fixtures
Showerheads 4 star, toilets 6 star, kitchen taps 6 star, basin taps 6 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
aluminium frames 280.5 m², single glazing 7 m², double glazing 273.5 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground (no added insulation)
  • Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: no frame (no added insulation)
  • Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (polystyrene)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
  • Floor: suspended floor above garage, concrete - suspended; frame: no frame (fibreglass batts or roll)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: cavity brick; frame: timber - H2 treated softwood. all external walls rockwool batts, roll or pump-in
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, timber - H2 treated softwood (ceiling: rockwool batts, roll or pump-in; roof: none.)

Certificate 1378675S, issued 5 December 2023, from the council's DA documents.