North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
7 Susan Street Vincentia NSW 2540
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 2 kW of solar panels and a 4,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 71 against 69 for energy and 41 against 40 for water.
Key features
- Windows
- 22 windows and glazed doors: Aluminium Hinged Door - Single Glazed; Quantum Sliding Window - Single Glazed; Trend Quantum Sliding Door
- Wall insulation
- Fibreglass batts or roll; No added insulation
- Roof and ceiling insulation
- Roof Added insulation absorptance Roof Colour ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 1.30, medium colour
- Hot water
- Electric storage
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Aria Homes.
BASIX certificate
- Energy score
- 71 (target 69)
- Water score
- 41 (target 40)
- Thermal performance
- Pass
- Materials score
- -64
- Heating load
- 38 MJ/m² a year
- Cooling load
- 23 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 199.1 m²
- Unconditioned floor area
- 22.8 m²
- Site area
- 1,012 m²
- Roof area
- 251 m²
- Garden area
- 644 m²
- Climate zone
- NatHERS climate zone 18
- Hot water
- Electric storage
- Solar panels
- 2 kW
- Rainwater tank
- 4,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Maximum glazing
- aluminium frames 57.7 m², single glazing 57.7 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER < 2.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER < 2.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER < 2.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER < 2.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: light steel frame (fibreglass batts or roll)
- External wall: cavity brick; frame: no frame (no added insulation)
- External wall: framed (fibre cement sheet or boards); frame: light steel frame (fibreglass batts or roll)
- External garage wall: brick veneer; frame: light steel frame (fibreglass batts or roll)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: light steel frame (fibreglass batts or roll)
- Internal wall: plasterboard; frame: light steel frame (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, light steel frame (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, light steel frame (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1827938S_02, issued 15 January 2026, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- Hero 4.1
- Rated on
- 15 Jan 2026
- Living room glazing by direction
- N 10.8 m², E 3.6 m², W 5.8 m²
- All glazing by direction
- N 19.3 m², E 8.8 m², S 19.8 m², W 9.9 m²
Roof
- Added insulation absorptance Roof Colour ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 1.30, medium colour
- FLAT-01: Flat Framed / Skillion Metal Roof & Flat PB Ceiling 1.30, medium colour
- FLAT-02: Flat Framed / Skillion Metal Roof & Cathedral PB Ceiling (11°-33°) 1.30, medium colour
Window types
- TND-021-004 Aluminium Hinged Door - Single Glazed: U-value 5.9, SHGC 0.58
- TND-078-031 Quantum Sliding Window - Single Glazed: U-value 5.2, SHGC 0.58
- TND-917-008 Trend Quantum Sliding Door: U-value 6, SHGC 0.65
Window schedule
- BATHROOM, window TND-078-031: 1,200 × 1,570 mm facing W
- BED 1, window TND-078-031: 1,800 × 3,010 mm facing N
- BED 1, window TND-078-031: 600 × 1,570 mm facing E
- BED 2, window TND-078-031: 1,200 × 1,570 mm facing E
- BED 3, window TND-078-031: 1,800 × 2,410 mm facing S
- BED 4, window TND-078-031: 1,800 × 2,410 mm facing S
- BED 5, window TND-078-031: 1,800 × 2,410 mm facing S
- BED1 2 ENSUITE, window TND-078-031: 600 × 1,210 mm facing E
- ENTRY, window TND-021-004: 1,800 × 1,020 mm facing S
- ENTRY, window TND-021-004: 600 × 1,020 mm facing S
- GARAGE, window TND-078-031: 1,030 × 1,570 mm facing E
- KITCHEN/FAMILY, window TND-078-031: 1,800 × 3,010 mm facing N
- KITCHEN/FAMILY, window TND-078-031: 1,800 × 3,010 mm facing N
- KITCHEN/FAMILY, window TND-917-008: 2,400 × 2,410 mm facing W
- KITCHEN/FAMILY HALWS-065-041 W18: 600 × 3,008 mm facing E
- KITCHEN/FAMILY HALWS-065-041 W19: 600 × 3,008 mm facing E
- LAUNDRY, window TND-078-031: 1,200 × 850 mm facing N
- LAUNDRY, window TND-021-004: 2,400 × 820 mm facing N
- LDRY SHOWER, window TND-078-031: 1,200 × 610 mm facing W
- LDRY TOILET, window TND-078-031: 1,200 × 610 mm facing W
- MEDIA, window TND-078-031: 1,800 × 2,410 mm facing S
- WC, window TND-078-031: 1,200 × 610 mm facing W
Certificate HR-TJX1JY-03, issued 15 January 2026, from the council's DA documents. Verify this certificate
Is this your home? Ask us to remove these details.