68 Queen Mary Street Callala Beach NSW 2540

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7.3 stars out of 10. Its BASIX certificate commits it to a 2,200 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 70 against 69 for energy and 45 against 40 for water.

Key features

Windows
17 windows and glazed doors: Timber A SG Clear; Aluminium Sliding Window SG 4ETClr; Aluminium Sliding Door SG 4ETClr and 4 more types
Wall insulation
R2.5
Roof and ceiling insulation
Ceiling R4, roof Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, dark colour
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by Hotondo Southcoast.

BASIX certificate

Energy score
70 (target 69)
Water score
45 (target 40)
Thermal performance
Pass
Materials score
-33
Heating load
42 MJ/m² a year
Cooling load
14 MJ/m² a year
Bedrooms
4
Conditioned floor area
158 m²
Unconditioned floor area
14 m²
Site area
819 m²
Roof area
288 m²
Garden area
521 m²
Climate zone
NatHERS climate zone 18
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Rainwater tank
2,200 litres
Fixtures
Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 32.5 m², single glazing 32.5 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 2.5 star (cold zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 2.5 star (cold zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 2.5 star (cold zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 2.5 star (cold zone)

Construction and insulation

  • Floor: concrete slab on ground, 40% cement substitute, waffle pod slab (no added insulation)
  • Garage floor: concrete slab on ground, 40% cement substitute, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (foil/sarking)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1773901S, issued 20 November 2024, from the council's DA documents.

NatHERS certificate

Star rating
7.3 stars
Rated with
BERS Pro v5.2.3 (3.23)
Rated on
20 Nov 2024
Wall insulation
R2.5
Ceiling insulation
R4
Floor insulation
R2.5, R2
LED downlights
49
Living room glazing by direction
NE 3.2 m², SE 4.3 m², NW 12.2 m²
All glazing by direction
NE 3.2 m², SE 13 m², NW 19.6 m²

Roof

  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, dark colour

Window types

  • TIM-001-01 W Timber A SG Clear: U-value 5.4, SHGC 0.56
  • DOW-001-015 Aluminium Sliding Window SG 4ETClr: U-value 4.5, SHGC 0.63
  • DOW-006-017 Aluminium Sliding Door SG 4ETClr: U-value 4.4, SHGC 0.61
  • DOW-014-015 Aluminium Fixed Window SG 4ETClr: U-value 4.3, SHGC 0.64
  • DOW-001-001 Aluminium Sliding Window SG 3Clr: U-value 6.4, SHGC 0.75
  • DOW-002-001 Aluminium Awning Window SG 3Clr: U-value 6.4, SHGC 0.65
  • DOW-002-015 Aluminium Awning Window SG 4ETClr: U-value 4.8, SHGC 0.55

Window schedule

  • Kitchen/Living, window DOW-001-015: 1,800 × 1,800 mm facing NW
  • Kitchen/Living, window DOW-006-017: 2,100 × 2,700 mm facing NW
  • Kitchen/Living, window DOW-014-015: 650 × 2,500 mm facing NW
  • Kitchen/Living, window DOW-014-015: 650 × 2,500 mm facing NW
  • Kitchen/Living, window DOW-001-015: 1,800 × 1,800 mm facing NE
  • BATH, window DOW-001-001: 1,200 × 1,500 mm facing NW
  • WC, window DOW-002-001: 1,800 × 600 mm facing NW
  • LDRY, window TIM-001-01 W: 900 × 820 mm facing NW
  • Bedroom 3, window DOW-002-015: 1,800 × 1,200 mm facing SE
  • Bedroom 2, window DOW-002-015: 1,800 × 1,200 mm facing SE
  • LIVING, window DOW-002-015: 1,800 × 1,200 mm facing SE
  • LIVING, window DOW-002-015: 1,800 × 1,200 mm facing SE
  • MASTER, window DOW-002-015: 1,800 × 1,200 mm facing SE
  • MASTER, window DOW-002-015: 1,800 × 1,200 mm facing SE
  • ENS, window DOW-002-001: 1,800 × 600 mm facing NW
  • ENS WC, window DOW-001-001: 900 × 600 mm facing NW
  • Bedroom 4, window DOW-001-015: 1,200 × 1,800 mm facing NW

Certificate 0011568235, issued 20 November 2024, from the council's DA documents.