Skip to main content

63 Canberra Crescent Burrill Lake NSW 2539

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to 2 kW of solar panels and a 5,000 litre rainwater tank. It beat its BASIX energy target, scoring 87 against 69.

Key features

Windows
22 windows and glazed doors: Composite A DG Argon Fill Low Solar Gain low-E -Clear; Composite B DG Argon Fill Low Solar Gain low-E -Clear
Wall insulation
Rockwool batts, roll or pump-in
Roof and ceiling insulation
Roof Added insulation absorptance Roof Colour Roof type Added insulation absorptance Roof Colour ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 0.00, medium colour
Hot water
Electric boosted solar with a performance of 31 to 35 STCs or better
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

Built by Wilford Constructions.

BASIX certificate

Energy score
87 (target 69)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-81
Heating load
36 MJ/m² a year
Cooling load
24 MJ/m² a year
Bedrooms
3
Conditioned floor area
202 m²
Unconditioned floor area
32.5 m²
Site area
557 m²
Roof area
242 m²
Garden area
100 m²
Climate zone
NatHERS climate zone 18
Hot water
Electric boosted solar with a performance of 31 to 35 STCs or better
Solar panels
2 kW
Rainwater tank
5,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
composite frames 68.1 m², double glazing 68.1 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground (not specified)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (polyurethane)
  • Floor: suspended floor above garage, concrete - suspended; frame: no frame (polyurethane)
  • Garage floor: concrete slab on ground (not specified)
  • External wall: cavity brick; frame: timber - untreated softwood (rockwool batts, roll or pump-in)
  • External wall: framed (metal clad); frame: timber - untreated softwood (rockwool batts, roll or pump-in)
  • External wall: framed (fibre cement sheet or boards); frame: timber - untreated softwood (rockwool batts, roll or pump-in)
  • External garage wall: cavity brick; frame: timber - untreated softwood (no added insulation)
  • Internal wall shared with garage: plasterboard; frame: timber - untreated softwood (rockwool batts, roll or pump-in)
  • Internal wall: plasterboard; frame: timber - untreated softwood (rockwool batts, roll or pump-in)

Certificate 1378966S, issued 7 December 2023, from the council's DA documents.

NatHERS certificate

Star rating
7.1 stars
Rated with
Hero 3.1.0.6
Rated on
06 Nov 2023
Living room glazing by direction
NE 16.8 m², SE 1.5 m², SW 8.7 m², NW 7.8 m²
All glazing by direction
NE 18.2 m², SE 12.8 m², SW 21.8 m², NW 14.4 m²

Roof

  • Added insulation absorptance Roof Colour Roof type Added insulation absorptance Roof Colour ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 0.00, medium colour
  • ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 1.30, medium colour

Window types

  • CMP-005-04 I Composite A DG Argon Fill Low Solar Gain low-E -Clear: U-value 2.2, SHGC 0.32
  • CMP-006-04 I Composite B DG Argon Fill Low Solar Gain low-E -Clear: U-value 2.23, SHGC 0.39

Window schedule

  • Entry, window CMP-006-04 I: 2,100 × 700 mm facing SW
  • Garage 1, window CMP-006-04 I: 600 × 610 mm facing SE
  • bath, window CMP-006-04 I: 600 × 610 mm facing NW
  • bathroom, window CMP-006-04 I: 2,100 × 700 mm facing SE
  • bed 2, window CMP-006-04 I: 860 × 2,410 mm facing NW
  • bed 3, window CMP-006-04 I: 2,400 × 3,000 mm facing SW
  • bed 3, window CMP-006-04 I: 1,000 × 2,700 mm facing SE
  • ensuite, window CMP-006-04 I: 900 × 1,810 mm facing NW
  • ensuite, window CMP-006-04 I: 900 × 1,510 mm facing NE
  • living/dining, window CMP-006-04 I: 860 × 2,410 mm facing NW
  • living/dining, window CMP-006-04 I: 2,400 × 7,000 mm facing NE
  • living/dining, window CMP-006-04 I: 600 × 2,410 mm facing SE
  • lounge/sitting, window CMP-006-04 I: 2,400 × 3,000 mm facing SW
  • lounge/sitting, window CMP-006-04 I: 2,160 × 700 mm facing SW
  • lounge/sitting, window CMP-006-04 I: 1,370 × 2,700 mm facing NW
  • lounge/sitting, window CMP-006-04 I: 860 × 2,410 mm facing NW
  • master, window CMP-006-04 I: 1,200 × 3,700 mm facing SW
  • master, window CMP-006-04 I: 900 × 2,710 mm facing NW
  • master, window CMP-006-04 I: 1,900 × 1,110 mm facing SE
  • master, window CMP-006-04 I: 1,900 × 1,110 mm facing SE
  • pantry, window CMP-006-04 I: 600 × 1,450 mm facing SE
  • storage, window CMP-005-04 I: 1,900 × 900 mm facing SE

Certificate HR-V21091-01, issued 6 November 2023, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related