North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
62 Wirraway Boulevard Badagarang NSW 2540
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 2,750 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 67 against 66.
Key features
- Windows
- 14 windows and glazed doors: Al Thermally Broken B DG Argon Fill High Solar; Composite B DG Argon Fill High Solar Gain low-E; Timber A SG Clear
- Wall insulation
- R2.5
- Roof and ceiling insulation
- Ceiling R5, R3.5, roof Corrugated Iron Steel Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, light colour
- Hot water
- Electric heat pump with a performance of 15 to 20 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Mdtd.
BASIX certificate
- Energy score
- 67 (target 66)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -32
- Heating load
- 51 MJ/m² a year
- Cooling load
- 10 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 93.7 m²
- Unconditioned floor area
- 10.2 m²
- Site area
- 336 m²
- Roof area
- 179 m²
- Garden area
- 171 m²
- Climate zone
- NatHERS climate zone 18
- Hot water
- Electric heat pump with a performance of 15 to 20 STCs or better
- Rainwater tank
- 2,750 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 25.4 m², timber frames 0.8 m², single glazing 0.8 m², double glazing 25.4 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: framed (fibre cement sheet or boards); frame: light steel frame (fibreglass batts or roll)
- External wall: brick veneer; frame: light steel frame (fibreglass batts or roll)
- External garage wall: brick veneer; frame: light steel frame (no added insulation)
- Internal wall: plasterboard; frame: light steel frame (fibreglass batts or roll)
- Internal wall: plasterboard; frame: light steel frame (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, light steel frame (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1831748S_02, issued 17 February 2026, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- BERS Pro v5.2.6 (3.23)
- Rated on
- 23 Feb 2026
- Wall insulation
- R2.5
- Ceiling insulation
- R5, R3.5
- Floor insulation
- R2.5, R2
- LED downlights
- 26
- Living room glazing by direction
- N 3.8 m², E 3 m², S 1.7 m², W 4.3 m²
- All glazing by direction
- N 3.8 m², E 7 m², S 8.2 m², W 7.2 m²
Roof
- Corrugated Iron Steel Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, light colour
Window types
- ATB-006-03 B Al Thermally Broken B DG Argon Fill High Solar: U-value 2.9, SHGC 0.51
- CMP-006-03 I Composite B DG Argon Fill High Solar Gain low-E: U-value 3.2, SHGC 0.49
- TIM-001-01 W Timber A SG Clear: U-value 5.4, SHGC 0.56
Window schedule
- Kitchen/Living1, window ATB-006-03 B: 2,100 × 1,800 mm facing N
- Kitchen/Living1, window ATB-006-03 B: 1,200 × 1,800 mm facing E
- Kitchen/Living1, window ATB-006-03 B: 450 × 1,800 mm facing E
- Kitchen/Living1, window CMP-006-03 I: 2,100 × 820 mm facing S
- Kitchen/Living1, window ATB-006-03 B: 1,800 × 2,400 mm facing W
- Laundry, window TIM-001-01 W: 1,000 × 820 mm facing E
- Bath, window CMP-006-03 I: 900 × 1,200 mm facing E
- Bed 3, window CMP-006-03 I: 1,200 × 1,800 mm facing E
- Bed 3, window CMP-006-03 I: 1,800 × 900 mm facing S
- Bed 3, window CMP-006-03 I: 1,800 × 900 mm facing S
- Master, window CMP-006-03 I: 1,800 × 900 mm facing S
- Master, window CMP-006-03 I: 1,800 × 900 mm facing S
- Ens, window CMP-006-03 I: 600 × 1,200 mm facing W
- Bed 2, window CMP-006-03 I: 1,200 × 1,800 mm facing W
Certificate 0012751160-02, issued 23 February 2026, from the council's DA documents. Verify this certificate
Is this your home? Ask us to remove these details.